QIAcuity EG PCR Kit

Para uso con los instrumentos de PCR digital QIAcuity

S_9797_dPCR_QIAcuity_EG_PCR_Kit

✓ 24/7 automatic processing of online orders

✓ Knowledgeable and professional Product & Technical Support

✓ Fast and reliable (re)-ordering

QIAcuity EG PCR Kit (1 ml)

Cat. No. / ID:   250111

QIAcuity EvaGreen Mastermix (mezcla maestra para QIAcuity EvaGreen) 1 ml con concentración de 3x, agua 2 × 1,9 ml
19.000 JPY
Log in To see your account pricing.
Volume
1 ml
5 ml
25 ml
El QIAcuity EG PCR Kit está concebido para su uso en aplicaciones de biología molecular. Este producto no está concebido para el diagnóstico, la prevención ni el tratamiento de enfermedades.

✓ 24/7 automatic processing of online orders

✓ Knowledgeable and professional Product & Technical Support

✓ Fast and reliable (re)-ordering

Features

  • Para reacciones de PCR digital basadas en colorante en las que se utiliza EvaGreen
  • Mezcla maestra con concentración de 3× para cargar más muestra
  • Optimizado para el uso de microfluidos en QIAcuity Nanoplates
  • Conforme a la norma REACH

Product Details

El QIAcuity EG PCR Kit contiene mezcla maestra lista para usar con concentración de 3× optimizada para el uso de microfluidos en las QIAcuity Nanoplates. El kit mejora la especificidad y la eficacia de la PCR digital basada en colorante para ofrecer análisis de cuantificación exactos. Un colorante de intercalado EvaGreen se une al ADN de doble cadena y mejora la exactitud cuantitativa de las mediciones de ADNg o ADNc en los instrumentos de dPCR QIAcuity.

El kit funciona junto con el QIAcuity Digital PCR System y las QIAcuity Nanoplates.

¿Le gustaría obtener más información sobre el producto y que uno de nuestros especialistas en dPCR se ponga en contacto con usted? Regístrese aquí y nos pondremos en contacto con usted en breve.

Performance

Rendimiento superior
Las QIAcuity Master Mixes para la detección basada en EvaGreen utilizan las versiones más recientes de ADN polimerasa de alta calidad de QIAGEN. La combinación única de la patentada tecnología de tampón de eficacia comprobada de QIAGEN optimizada para microfluidos de nanoplacas, junto con el nuevo QuantiNova DNA Polymerase permite obtener resultados uniformes en lo que respecta a sensibilidad, reproducibilidad y eficacia.

Detección basada en colorante con EvaGreen
La mezcla maestra especial del QIAcuity EG PCR Kit permite la amplificación y cuantificación exactas de blanco de ADN de doble cadena. Incluye un colorante de referencia optimizado necesario para el análisis de dPCR y el recuento de divisiones analizables en las Nanoplates. Además, EvaGreen proporciona una señal de fluorescencia más elevada que SYBR Green en las mismas concentraciones y ofrece máxima amplificación, eficiencia, especificidad y sensibilidad en dPCR.

Estabilidad en la reacción de hasta 100 horas
Las mezclas para PCR QIAcuity pueden almacenarse a una temperatura de 30 °C durante un máximo de 100 horas sin que se altere el rendimiento de las reacciones posteriores. La excelente estabilidad, incluso tras un almacenamiento prolongado a temperatura ambiente sin el uso de ningún agente refrigerante hace que el QIAcuity EG PCR Kit sea ideal para la configuración de reacciones de alto rendimiento y la manipulación de pilas de placas.

Principle

El QIAcuity EG PCR Kit proporciona análisis de ADNc o ADNg con máxima especificidad gracias a su novedoso mecanismo de inicio en caliente mediado por anticuerpos. A bajas temperaturas, el QuantiNova DNA Polymerase se mantiene en un estado inactivo por acción del anticuerpo QuantiNova Antibody y un nuevo aditivo, QuantiNova Guard, que estabiliza el complejo. De esta manera, se mejora la astringencia del inicio en caliente y previene la extensión de oligonucleótidos alineados de manera no específica y de dímeros de oligonucleótidos. A los 2 minutos de haber alcanzado una temperatura de 95 °C, el QuantiNova Antibody y el QuantiNova Guard se desnaturalizan y se activa la QuantiNova DNA Polymerase, lo que permite la amplificación por PCR.

El principio de la reacción de dPCR en las nanoplacas se describe aquí.

Procedure

Al igual que en los experimentos de qPCR, la preparación de las muestras incluye la transferencia de mezcla maestra, sondas y cebadores a una nanoplaca de 96 o 24 pocillos, seguida de la adición de las muestras. El sistema integra funciones de división en partes, termociclado y obtención de imágenes en un solo instrumento completamente automatizado que permite a los usuarios obtener los resultados de las muestras en menos de 2 horas. Es posible realizar un análisis en el paquete de software, que proporciona la concentración en copias por microlitro de la secuencia de blancos y también para el control de calidad como muestras positivas o NTC. Este análisis también se puede extender a ordenadores remotos dentro de la misma red de área local (LAN).

Applications

El QIAcuity EG PCR Kit, junto con el QIAcuity Digital PCR System y las QIAcuity Nanoplates, permiten el análisis cuantitativo de blancos de ADNc y ADNg para utilizarlas en aplicaciones, entre las que se incluyen:

  • Detección de mutaciones poco frecuentes
  • Análisis de variación en el número de copias
  • Análisis de expresión génica
  • Detección de microrganismos patógenos
  • Genotipado
  • Investigación sobre miARN

Supporting data and figures

Resources

Operating Software (15)
QIAcuity Software Suite
SOFTWARE (381MB)
Version 1.1.3
For Version 2
Version 4.0

The Volume Precision Factor (VPF) offers a unique feature to secure precision of concentration results obtained from a QIAcuity dPCR run. 
In general, Nanoplates provide partitions of fixed sizes that enable a very precise way of sample concentration calculation. Potential variation of partition sizes in Nanoplate batches, caused by different microstructure molding forms, can be addressed by applying the batch specific VPF. Furthermore, the VPF includes well-specific volume information and therefore further increases precision of concentration calculation in each well of the Nanoplates.

After downloading and updating the VPF file within the QIAcuity Software Suite, the VPF is applied automatically to the analysis of a corresponding Nanoplate batch. The VPF file includes information from all available microstructure molding forms and connected Nanoplate batches. It will be stored on the PC where the QIAcuity Software Suite is installed. 

Required QIAcuity Software Suite version: Version 1.2 or higher.

Version 2.1

 

Beside of usability improvements and bug fixes, the new features address GMP requirements by offering additional support for 21 CFR part 11 compliance, copy number variation (CNV) analysis, support of future Nanoplates, and improved 1D scatterplot views.

For more information, please refer to the Release Note: QIAcuity Software Suite, Version 2.1

 

SHA1 checksum: 6D51E273B26FA7D7E0EDA843CB3DCD74B38FA5B1

 

QIAcuity Control Software
SOFTWARE (401MB)
Version 2.0

The QIAcuity Control Software is an integral part of the QIAcuity instrument. It offers a GUI (graphical user interface) for basic functionalities such as plate setup, changing the order of plates to be processed, and monitoring the status of runs in real time. After a run is completed, the data are stored on the instrument’s memory and are sent to the connected QIAcuity Software Suite for analysis

Besides system stability and performance reliability improvements, this new version of the control software offers advanced user management and audit trail functionalities. Together with the QIAcuity Software Suite 2.0, the QIAcuity systems now support 21 CFR Part 11 regulations for users working under GMP.

Detailed information is available in the Release Note, which can also be downloaded under section “Operating Software”.

Note: Upgrading the QIAcuity Control Software to version 2.0 will require upgrading the QIAcuity Software Suite to version 2.0.

Important: Please follow the instructions provided in the QIAcuity User Manual for software version 2.0. It is strongly recommended to update the QIAcuity Software Suite first before proceeding with the QIAcuity Control Software!
QIAcuity Control Software
SOFTWARE (263MB)
Version 1.0

The QIAcuity Control Software is an integral part of the QIAcuity instrument. It offers a GUI (graphical user interface) for basic functionalities such as plate setup, changing the order of plates to be processed, and monitoring the status of runs in real time. After a run is completed, the data are stored on the instrument’s memory and are sent to the connected QIAcuity Software Suite for analysis.

This new version of the control software includes system stability and performance reliability improvements. We highly recommend to update the control software of your QIAcuity instrument.

Note: The installation requires approximately 90 minutes.

Version 2.0

The QIAcuity Software Suite 2.0 is designed to be installed on a Windows PC that is connected to one or more QIAcuity instruments. The QIAcuity Software Suite enables the user to set up plates, analyze results, and monitor the status of runs in real time. For this configuration, the QIAcuity instrument needs to be connected to a network through Ethernet. Alternatively, a direct cable connection between the QIAcuity and the notebook where the QIAcuity Software Suite is running needs to be established. When connected to a network, up to 10 users may access the QIAcuity Software Suite via a browser installed on the client PC (Windows or Mac).

This new software version  now supports 21 CFR Part 11 regulations for users working under GMP. This includes the following:

-Advanced User Management
-Audit Trail
-Signatures

Additional changes compared with the previous software version include the following:

-Usability improvements
-Improved dust detection
-Hyperwell expansion to CNV and GEX analysis
-CSV export functionality of multiple positive partitions for linkage analysis, drop-off assays, etc.
-Raw data export

Detailed information is available in the Release Note, which can also be downloaded under section “Operating Software”.

Important: A direct update of the Software Suite from version 1.1.3 to 2.0.20 is not possible. Please follow the instructions in the User Manual on how to update to version 1.2.18 first before updating the Software Suite to version 2.0.20.

Before you start upgrading to version 1.1.3, please make sure that all plates are imported and visible in the plate overview of the QIAcuity Software Suite.

Caution: Not following the instructions may result in a loss of your previous plate data!

Please contact QIAGEN Technical Services if you are unsure and require technical support.


SHA1 checksum
​: C60C4EEC349DF1C037796016D32A93EEC19B54A0 

Version 2.1

Version 2.1

 

Beside of improvements and bug fixes, the new features mainly address the GMP requirements by offering additional support for 21 CFR part 11 compliance and get the software ready for future Nanoplate support.

For more information, please refer to the Release Note: QIAcuity Instrument Control Software, Version 2.1.

SHA1 checksum: 0DD41A8DE46D10E81F538ACB71AC184170D39FE0

QIAcuity Software Suite
SOFTWARE (389MB)

Version 1.2

The QIAcuity Software Suite 1.2 is designed to be installed on a Windows PC that is connected to one or more QIAcuity instruments. The QIAcuity Software Suite enables the user to set up plates, analyze results, and monitor the status of runs in real time. For this configuration, the QIAcuity instrument needs to be connected to a network through Ethernet. Alternatively, a direct cable connection between the QIAcuity and the notebook where the QIAcuity Software Suite is running needs to be established. When connected to a network, up to 10 users may access the QIAcuity Software Suite via a browser installed on the client PC (Windows or Mac).

The following browsers are supported in the QIAcuity Software Suite:

-Mozilla Firefox (version 64.0.2 or higher)
-Microsoft Edge (version 44.17763.1.0 or higher)
-Google Chrome (version 71.0.3578.98 or higher)

The new QIAcuity Software Suite 1.2 offers a functionality that enables users of the QIAcuity Software 1.1.3 to upgrade to the new version while keeping the library of previously stored plate runs.

Note: If you have exported plates from QIAcuity Software Suite 1.1.3 that you would like to import and use in QIAcuity Software Suite 1.2, you will need to import the plates before upgrading from version 1.1.3 to version 1.2. You may then export the plates again. Future software version starting from QIAcuity Software Suite 2.0 will facilitate import of plates from previous QIAcuity Software Suite versions.

The new improvements are as follows:

-Support for the Nanoplate 8.5k 24-well
-Hyperwell functionality to combine several wells to one combined well for analysis
-Automated plate archiving functionality
-Functionality to show the number of single/double positives in 2D scatterplots
-VPF (Volume Precision Factor) to further improve concentration calculation (see related resources)
-Additional improvements for stabilization and troubleshooting

For Version 1.2

Version 2.0

The QIAcuity Software Suite 2.0 is designed to be installed on a Windows PC that is connected to one or more QIAcuity instruments. The QIAcuity Software Suite enables the user to set up plates, analyze results, and monitor the status of runs in real time. For this configuration, the QIAcuity instrument needs to be connected to a network through Ethernet. Alternatively, a direct cable connection between the QIAcuity and the notebook where the QIAcuity Software Suite is running needs to be established. When connected to a network, up to 10 users may access the QIAcuity Software Suite via a browser installed on the client PC (Windows or Mac).

This new software version  now supports 21 CFR Part 11 regulations for users working under GMP. This includes the following:

-Advanced User Management
-Audit Trail
-Signatures

Additional changes compared with the previous software version include the following:

-Usability improvements
-Improved dust detection
-Hyperwell expansion to CNV and GEX analysis
-CSV export functionality of multiple positive partitions for linkage analysis, drop-off assays, etc.
-Raw data export

Detailed information is available in the Release Note, which can also be downloaded under section “Operating Software”.

Important: A direct update of the Software Suite from version 1.1.3 to 2.0.20 is not possible. Please follow the instructions in the User Manual on how to update to version 1.2.18 first before updating the Software Suite to version 2.0.20.

Before you start upgrading to version 1.1.3, please make sure that all plates are imported and visible in the plate overview of the QIAcuity Software Suite.

Caution: Not following the instructions may result in a loss of your previous plate data!

Please contact QIAGEN Technical Services if you are unsure and require technical support.


SHA1 checksum
​: C60C4EEC349DF1C037796016D32A93EEC19B54A0 

Instrument User Manuals (2)
Webinars (5)
Limitations of conventional PCR and qPCR when dealing with difficult, low-volume samples and complex mixtures with high background of competitive molecules and inhibitors have posed frequent challenges for researchers and clinicians in their routine work. With the new generation of PCR technologies, digital PCR has opened doors for diverse applications, and researchers are learning to ask questions only digital PCR can answer. Join QIAGEN's webinar on how digital PCR can help take your research applications through and beyond those challenges.
This presentation will introduce dPCR, discuss its advantages, and outline how the approach might be used to improve measurement in areas like clinical diagnosis, alone or in conjunction with other methods.
In this expert webinar, Dr. Kubista will share with you the experience he and his team have gathered at the TATAA Biocenter, developing applications and providing services using digital PCR for nearly 12 years. They have experienced all the problems common to dPCR analytical workflows and developed robust standard operating procedures to minimize the risk of error and maximize robustness and repeatability, and developed various controls to test the performance and validate the methods. He will also discuss dPCR assay design and validation and then focus on strategies for copy number determination and rare mutation detection.
The QIAGEN digital PCR technology and its expanded capability will not only transform the portfolio of conventional qPCR applications but also provide a more rapid, accurate, and sensitive method for finding answers to difficult biological questions. 
As the digital PCR technology evolves and becomes more accessible and affordable, the transition from qPCR and adoption of dPCR will hopefully no longer remain a challenge. Experts share insights in an upcoming webinar about the fully integrated, rapid, and highly flexible digital PCR portfolio from QIAGEN. 
Kit Handbooks (1)
For highly sensitive detection of miRNA using EvaGreen
Certificates of Analysis (1)

FAQ

Can I use the QIAcuity Nanoplate in more than one runs?

The plate is designed for a single use run. For example, even if only 30 samples are loaded into the 96-well plate, a whole plate will be sealed by the roller. It can't be unsealed and used for another run. The QIAcuity Software won’t allow to set up a separate experiment for the same nanoplate to avoid that previously processed plates being not partitioned a second time.

3781
What are the storage conditions and expiry date of QIAcuity consumables?
The QIAcuity Probe PCR Kit should be stored immediately upon receipt at –30 to –15°C in a constant-temperature freezer and protected from light. The QIAcuity Probe PCR master mix can also be stored protected from light at 2–8°C. Components are stable for 12 months, unless otherwise indicated on the label. 
The QIAcuity EG PCR Kit should be stored immediately upon receipt at –30 to –15°C in a constant-temperature freezer and protected from light. The QIAcuity EG PCR master mix can also be stored protected from light at 2–8°C. Components are stable for 6 months, unless otherwise indicated on the label. 
The QIAcuity Nanoplates does not have expiry date and are stable for at least 1 year when stored at RT. 
FAQ ID - 9214
Where can I find assays specifically designed for QIAcuity?
QIAGEN dPCR assays (such as dPCR LNA Mutation Assays) can be found on https://geneglobe.qiagen.com/.
FAQ ID - 9207
Can I prepare a dPCR reaction directly in QIAcuity Nanoplate?

A standard PCR plate is required to set up dPCR reaction before transferring it to the nanoplate to ensure a proper mixing of the reaction mix before partitioning. 

3774
How can I get the latest VPF (Volume Precision Factor)?
The up-to-date VPF can be downloaded in the resource section of the QIAcuity product webpage. The VPF  is compatible with the QIAcuity Software Suite 1.2 and higher. The latest VPF file contains all factors for all existing nanoplate batches. If a nanoplate from a new nanoplate batch is run and the latest version of the VPF was not installed, the software will recognize this and will give a message to install the latest VPF file. Please note that Applying the VPF file cannot be reversed.
FAQ ID - 9206
What is the VPF (Volume Precision Factor)?
The VPF provides a set of well-specific and molding form-specific factors used to specify the exact reaction volume of a nanoplate, thus increasing the concentration calculation of each well. 
FAQ ID - 9218
Where can I find assays specifically designed for QIAcuity?

QIAGEN dPCR assays (such as dPCR LNA Mutation Assays) can be found on https://geneglobe.qiagen.com/.

3773
Is it possible to change voltage set-up from 110V to 230V on the QIAcuity instruments?

This is not needed. The QIAcuity is equipped with a flexible power supply technology and operates within a range of 100–240V AC, 50/60 Hz, 1500 VA (max). 

3761
What is the impact of not applying the latest VPF? Can I reanalyze previously obtained results after installing the latest VPF?

If you had run a nanoplate for which the installed VPF misses the specific factor, the software will notify you. If you then analyze without the specific VPF, the impact depends on the variation of the partition volume of the new Nanoplate batch compared to the latest. Typically this variation is ±6–7% (approx. 5% CV over the entire plate). The analysis may be repeated after updating the VPF file. After installing the latest VPF and re-analysis of the run, a copy of the plate is generated in the QIAcuity Software Suite including the new results. 

3769
Can I use a custom master mix instead of a QIAGEN master mix?

QIAGEN master mixes are optimized for nanoplate microfluidics and are recommended to be used with our dPCR system. They also include an optimized reference dye required for proper analysis.

3777
Does an incorrect handling of a plate might affect the results?
The QIAcuity reads emitted fluorescence from the bottom of the plate, which is covered with a foil. For best results, keep the foil clean and avoid damages such as scratches. Also, keep the barcode on the side of the plate clean and intact. Ensure that you wear gloves when working with a plate and do not apply force to it. For a safe handling of the plate, please  place the plate into a nanoplate tray.
FAQ ID - 9202
Can I use a custom master mix instead of a QIAGEN master mix?
QIAGEN master mixes are optimized for nanoplate microfluidics and are recommended to be used with our dPCR system. They also include an optimized reference dye required for proper analysis.
FAQ ID - 9211
Can I optimize a dPCR assay on the QIAcuity using gradient temperature?

QIAcuity does not support temperature gradient in PCR cycling profile. However, optimization of a dPCR assay can be done by qPCR on a gradient cycler using the dPCR master mix and then transferred from qPCR to dPCR. 

3783
Which sample preparation method is recommended for QIAcuity dPCR?
QIAGEN offers a complete range of nucleic acid purification systems. These include QIAprep kits for purification of plasmid DNA, QIAamp and DNeasy kits for purification of genomic DNA, RNeasy kits for purification of total RNA, and the PAXgene Blood RNA System for stabilization and purification of RNA from blood. Phenol and other contaminants can be efficiently removed from crude RNA preps using the RNeasy MinElute Cleanup Kit to clean up and concentrate RNA for sensitive assays. Details about QIAGEN kits for nucleic acid purification can be found at www.qiagen.com.
FAQ ID - 9213
Can I use an empty nanoplate without seal to perform a dry run?
The QIAcuity instrument software does not allow to read and process a plate without seal. If you would like to perform a dry run please use sealed plate and set up this plate in the QIAcuity Software Suite. 
FAQ ID - 9201
Can I use the dPCR master mix in a qPCR cycler for optimization purposes?
dPCR master mix can be used in qPCR to optimize sample concentration and/or primer/probe concentration prior to assay transfer from qPCR to dPCR. 
FAQ ID - 9209
Is it possible to change voltage set-up from 110V to 230V on the QIAcuity instruments?
This is not needed. The QIAcuity is equipped with a flexible power supply technology and operates within a range of 100–240V AC, 50/60 Hz, 1500 VA (max). 
FAQ ID - 9195
How are results stored within the QIAcuity Software Suite?
Results are stored as part of the plates within the QIAcuity Software Suite. In version 1.1.2, plates can be exported to another file location, for example, an external HDD, and imported again if needed. From version 1.2 onwards, plates can also be archived automatically. To do so, an archive destination has to be defined. Additional information can be found in the user manual. 
FAQ ID - 9198
Which sample preparation method is recommended for QIAcuity dPCR?

QIAGEN offers a complete range of nucleic acid purification systems. These include QIAprep kits for purification of plasmid DNA, QIAamp, and DNeasy kits for purification of genomic DNA, RNeasy kits for purification of total RNA, and the PAXgene Blood RNA System for stabilization and purification of RNA from blood. Phenol and other contaminants can be efficiently removed from crude RNA preps using the RNeasy MinElute Cleanup Kit to clean up and concentrate RNA for sensitive assays. Details about QIAGEN kits for nucleic acid purification can be found at www.qiagen.com.

3779
Is it necessary to reanalyze a plate with VPF (Volume Precision Factor) that was already processed using a QIAcuity instrument that was purchased in 2020?

If you had analyzed your nanoplates without VFP, the impact depends on the variation of the partition volume of the new nanoplate batch compared to the latest. The VPF reduces the CV from approximately 5% to 2%. We recommend to reanalyze results in case the data originated from different wells (e.g., copy number variations or gene expression data sets for which the reference sample was measured in a different well). Results obtained across different plates should also be r-analyzed. A reanalysis is not required for assay data that were analyzed within the same well (e.g., mutation rate determination using two channels within the same well).

3771
Is a standard curve needed in dPCR?

In dPCR we measure the absolute concentration of targets at endpoint reaction. Concentrations of unknowns can be determined based on dPCR results observed (number of negatives, number of positives, and partition volume analyzed).

3786
How can I upgrade the software on the instrument (CSW) and the QIAcuity Software Suite?
Both software are designed to be upgraded by users. The user manual includes instructions on how to perform the upgrades; instructions for the QIAcuity Suite Software upgrade can be found at page 38 and instructions for the CSW upgrade on page 67 (QIAcuity User Manual, 03/2021).  
FAQ ID - 9196
Is it necessary to reanalyze a plate with VPF (Volume Precision Factor) that was already processed using a QIAcuity instrument that was purchased in 2020?
If you had analyzed your nanoplates without VFP, the impact depends on the variation of the partition volume of the new nanoplate batch compared to the latest. The VPF reduces the CV from approximately 5% to 2%. We recommend to re-analyze results in case the data originated from different wells (e.g., copy number variations or gene expression data sets for which the reference sample was measured in a different well). Results obtained across different plates should also be re-analyzed. A re-analysis is not required for assay data that were analyzed within the same well (e.g., mutation rate determination using two channels within the same well).
FAQ ID - 9205
When and how often do I need a new VPF (Volume Precision Factor)?

 In general, nanoplates provide partitions of fixed sizes that enable a very precise way of sample concentration calculation. If a new molding form is used for nanoplate manufacturing, potential variation of partition sizes can be addressed by applying the molding form-specific VPF. Thus, each time a new molding form is used, a new VPF is created and made available. Currently, the VPF is updated once every 3–6 months.

3785
When and how often do I need a new VPF (Volume Precision Factor)?
 In general, nanoplates provide partitions of fixed sizes that enable a very precise way of sample concentration calculation. If a new molding form is used for nanoplate manufacturing, potential variation of partition sizes can be addressed by applying the molding form-specific VPF. Thus, each time a new molding form is used, a new VPF is created and made available. Currently, the VPF is updated once every 3–6 months.
FAQ ID - 9219
What is the input volume for QIAcuity Nanoplate well?
Nanoplate 26K 24-well: 40 μl 
Nanoplate 8.5K 24-well:12 μl 
Nanoplate 8.5K 96-well: 12 μl 
FAQ ID - 9216
What is the purpose of the reference channel in QIAcuity?
The fluorescent signal in the reference channel is measured to determine the number of valid partitions in a well. In addition, differences in the signal intensities between partitions are normalized and the fluorescent signals in the target channels are corrected accordingly.
FAQ ID - 9210
Is a standard curve needed in dPCR?
In dPCR, we measure the absolute concentration of targets at endpoint reaction. Concentrations of unknowns can be determined based on dPCR results observed (number of negatives, number of positives, and partition volume analyzed).
FAQ ID - 9220
What is the purpose of the reference channel in QIAcuity?

The fluorescent signal in the reference channel is measured to determine the number of valid partitions in a well. In addition, differences in the signal intensities between partitions are normalized and the fluorescent signals in the target channels are corrected accordingly.

3776
What is the VPF (Volume Precision Factor)?

The VPF provides a set of well-specific and molding form-specific factors used to specify the exact reaction volume of a nanoplate, thus increasing the concentration calculation of each well. 

3784
Can I see on the QIAcuity Software Suite report file if the VPF (Volume Precision Factor) has been used or not?

Yes, the report includes a notification if the matching VPF was missing and, therefore, not applied to the analysis. If the matching VPF was applied there is no notification on the report. 

3770
What are the storage conditions and expiry date of QIAcuity consumables?

The QIAcuity Probe PCR Kit should be stored immediately upon receipt at –30 to –15°C in a constant-temperature freezer and protected from light. The QIAcuity Probe PCR master mix can also be stored protected from light at 2–8°C. Components are stable for 12 months, unless otherwise indicated on the label. 
The QIAcuity EG PCR Kit should be stored immediately upon receipt at –30 to –15°C in a constant-temperature freezer and protected from light. The QIAcuity EG PCR master mix can also be stored protected from light at 2–8°C. Components are stable for 6 months, unless otherwise indicated on the label. 
The QIAcuity Nanoplates does not have expiry date and are stable for at least 1 year when stored at RT. 

3780
What is the input volume for QIAcuity Nanoplate well?

Nanoplate 26K 24-well: 40 μl 
Nanoplate 8.5K 24-well:12 μl 
Nanoplate 8.5K 96-well: 12 μl 

3782
How to prepare DNA prior to dPCR?

All DNA samples used in reaction mixes should show similar quality and quantity, which can easily be assessed using UV spectrophotometry. DNA samples with an average length of ≥20 kb (e.g., genomic DNA purified via spin column with silica membrane) should be fragmented by restriction digestion before partitioning. Enzymatic fragmentation of larger DNA ensures an even distribution of template throughout the QIAcuity Nanoplate, which in turn leads to an accurate and precise quantification.

3778
Can I see error codes on the instrument touchscreen?

The instrument software GUI shows error codes including a description and information how to resolve the error. The instrument touchscreen shows an alarm icon in the upper right corner that turns red in case of an instrument failure. Accessing the System Status in the Tool tab allows users to clear errors. Rebooting of the instrument is required to complete the removal of the error.  Please do not skip this step. You may always contact QIAGEN Technical Services in case of any question. 

3763
Can I use the QIAcuity Nanoplate in more than one runs?
The plate is designed for a single use run. For example, even if only 30 samples are loaded into the 96-well plate, a whole plate will be sealed by the roller. It can't be unsealed and used for another run. The QIAcuity Software won’t allow to set up a separate experiment for the same nanoplate to avoid that previously processed plates being not partitioned a second time.
FAQ ID - 9215
What is the impact of not applying the latest VPF? Can I reanalyze previously obtained results after installing the latest VPF?
If you had run a nanoplate for which the installed VPF misses the specific factor, the software will notify you. If you then analyze without the specific VPF, the impact depends on the variation of the partition volume of the new Nanoplate batch compared to the latest. Typically this variation is ±6–7% (approx. 5% CV over the entire plate). The analysis may be repeated after updating the VPF file. After installing the latest VPF and re-analysis of the run, a copy of the plate is generated in the QIAcuity Software Suite including the new results. 
FAQ ID - 9203
Can I see on the QIAcuity Software Suite report file if the VPF (Volume Precision Factor) has been used or not?
Yes, the report includes a notification if the matching VPF was missing and, therefore, not applied to the analysis. If the matching VPF was applied there is no notification on the report. 
FAQ ID - 9204
How to prepare DNA prior to dPCR?
All DNA samples used in reaction mixes should show similar quality and quantity, which can easily be assessed using UV spectrophotometry. DNA samples with an average length of ≥20 kb (e.g., genomic DNA purified via spin column with silica membrane) should be fragmented by restriction digestion before partitioning. Enzymatic fragmentation of larger DNA ensures an even distribution of template throughout the QIAcuity nanoplate, which in turn leads to an accurate and precise quantification.
FAQ ID - 9212
Can I use an empty nanoplate without seal to perform a dry run?

The QIAcuity instrument software does not allow to read and process a plate without seal. If you would like to perform a dry run please use sealed plate and set up this plate in the QIAcuity Software Suite. 

3767
Can I use the dPCR master mix in a qPCR cycler for optimization purposes?

dPCR master mix can be used in qPCR to optimize sample concentration and/or primer/probe concentration prior to assay transfer from qPCR to dPCR. 

3775
What is the scope of a regular maintenance of the QIAcuity?

The user manual contains instructions on how to perform a regular cleaning and decontamination, and how to replace air filters on the QIAcuity instruments. A regular maintenance reduces the dust in the instrument and therefore minimizes the presence of dust particles on the nanoplate, which might interfere with the plate analysis.

3765
How can I get the latest VPF (Volume Precision Factor)?

The up-to-date VPF can be downloaded in the resource section of the QIAcuity product webpage. The VPF  is compatible with the QIAcuity Software Suite 1.2 and higher. The latest VPF file contains all factors for all existing nanoplate batches. If a nanoplate from a new nanoplate batch is run and the latest version of the VPF was not installed, the software will recognize this and will give a message to install the latest VPF file. Please note that Applying the VPF file cannot be reversed.

3772
Does an incorrect handling of a plate might affect the results?

The QIAcuity reads emitted fluorescence from the bottom of the plate, which is covered with a foil. For best results, keep the foil clean and avoid damages such as scratches. Also, keep the barcode on the side of the plate clean and intact. Ensure that you wear gloves when working with a plate and do not apply force to it. For a safe handling of the plate, please  place the plate into a nanoplate tray.

3768
Can I see error codes on the instrument touchscreen?
The instrument software GUI shows error codes including a description and information how to resolve the error. The instrument touchscreen shows an alarm icon in the upper right corner that turns red in case of an instrument failure. Accessing the System Status in the Tool tab allows users to clear errors. Rebooting of the instrument is required to complete the removal of the error.  Please do not skip this step. You may always contact QIAGEN Technical Service in case of any question. 
FAQ ID - 9197
Can the QIAcuity One 2plex be upgrade to the QIAcuity One 5plex?
No. The QIAcuity platform introduces four variations: QIAcuity One 2plex, QIAcuity One 5plex, QIAcuity Four (5plex), and QIAcuity Eight (5plex). All of them have fix channel combination. 
FAQ ID - 9200
Can the QIAcuity One 2plex be upgrade to the QIAcuity One 5plex?

No. The QIAcuity platform introduces four variations: QIAcuity One 2plex, QIAcuity One 5plex, QIAcuity Four (5plex), and QIAcuity Eight (5plex). All of them have fix channel combination. 

3766
Can I prepare a dPCR reaction directly in QIAcuity Nanoplate?
A standard PCR plate is required to set up dPCR reaction before transferring it to the nanoplate to ensure a proper mixing of the reaction mix before partitioning. 
FAQ ID - 9208
Can I optimize a dPCR assay on the QIAcuity using gradient temperature?
QIAcuity does not support temperature gradient in PCR cycling profile. However, optimization of a dPCR assay can be done by qPCR on a gradient cycler using the dPCR master mix and then transferred from qPCR to dPCR. 
FAQ ID - 9217
How are results stored within the QIAcuity Software Suite?

Results are stored as part of the plates within the QIAcuity Software Suite. In version 1.1.2, plates can be exported to another file location, for example, an external HDD, and imported again if needed. From version 1.2 onwards, plates can also be archived automatically. To do so, an archive destination has to be defined. Additional information can be found in the user manual. 

3764
How can I upgrade the software on the instrument (CSW) and the QIAcuity Software Suite?

Both software are designed to be upgraded by users. The user manual includes instructions on how to perform the upgrades; instructions for the QIAcuity Suite Software upgrade can be found at page 38 and instructions for the CSW upgrade on page 67 (QIAcuity User Manual, 03/2021).  

3762
What is the scope of a regular maintenance of the QIAcuity?
The user manual contains instructions on how to perform a regular cleaning, decontamination, and how to replace air filters on the QIAcuity instruments. A regular maintenance reduces the dust in the instrument and therefore minimizes the presence of dust particles on the nanoplate, which might interfere with the plate analysis.
FAQ ID - 9199