QuantiNova LNA Probe PCR lncRNA Focus Panels

For accurate and reliable lncRNA quantification using LNA-enhanced, probe-based PCR

Products

QuantiNova LNA Probe PCR lncRNA Focus Panels are intended for molecular biology applications. These products are not intended for the diagnosis, prevention, or treatment of a disease.
Image

QuantiNova LNA Probe PCR lncRNA Focus Panels

Cat. No. / ID:   249956

Ready-to-use plate containing research area- or pathway-focused assays for lncRNA targets in 96- or 384-well format for any cycler. Minimum order is 1 plate; price discounted when ordering 6 or more copies of the same plate: 6-11 plates 25% off, 12-23 plates 40% off, >24 plates 55% off.

Features

  • Expert-designed panels targeting the highly relevant pathways or diseases
  • Simultaneous profiling of related lncRNAs based on the latest literature
  • Exceptional sensitivity and specificity using short, LNA-enhanced primers and FAM-labeled hydrolysis probes
  • Stability for room-temperature setup allowing automation
  • Robust and reproducible results in less than 2 hours using the QuantiNova Probe PCR Kit

Product Details

QuantiNova LNA Probe PCR lncRNA Focus Panels enable quick, accurate and sensitive expression analysis of disease- or pathway-related lncRNAs using hydrolysis probe-based qPCR. LNA enhancement enables us to design shorter primers with optimal Tm, allowing flexible positioning on the target for optimal sequence discrimination. Thorough design validation ensures top performance and robust detection. Optimized using QuantiNova chemistry, the simple workflow can be completed in under 2 hours and is robust enough to support room-temperature setup, automation and delayed run. We also offer Flexible Panels, which you can create from the assays in our Focus Panels, as well as Custom Panels with your choice of predesigned and/or custom assays.

Need a quote for your research project or would you like to discuss your project with our specialist team? Just contact us!

During the early release offering, only the mouse focus panels will be available. The human focus panels will be released soon.

Performance

Expert LNA enhancement for top qPCR performance

The assays in the QuantiNova LNA Probe PCR lncRNA Focus Panels have been developed using stringent design criteria and lab-validated algorithms. Twenty years of LNA design experience has enabled us to optimize our sophisticated LNA design algorithm, which incorporates over 50 different parameters to guarantee the most optimal assay for successful target detection. Each primer–probe set delivers the highest specificity and efficiency for the most reliable and accurate results. LNA enhancement enables Tm normalization across the panel, giving the primers and probes higher binding affinity, dramatically increasing assay sensitivity and specificity.

The increased sensitivity ensures excellent amplification efficiencies down to 1 RNA molecule, making it easier for you to detect low-abundance targets such as lncRNAs from less starting material (see figure  QuantiNova LNA Probe PCR Assays provide accurate, sensitive and linear quantification of targets over a wide dynamic range and figure  QuantiNova LNA Probe PCR Assays enable both high-expression and low-expression detection of mRNA). Increased specificity from the clever placement of LNA gives you a high signal-to-noise ratio, allowing discrimination of sequences that differ by only a single nucleotide and eliminating non-specific amplification and primer-dimer formation.

The high binding affinity of LNA bases increases the flexibility of primer and probe placement on the transcript, so we are able to use intelligent positioning to design assays for otherwise difficult-to-analyze targets. This gives you robust and reliable quantification, even for AU-rich targets, low-abundance transcripts, targets with high secondary structure and highly complex samples.

See figures

Principle

Robust and high-performance hydrolysis probe-based qPCR

QuantiNova LNA Probe PCR lncRNA Focus Panels use FAM-labeled hydrolysis probe-based detection, which is highly sensitive and robust, because only the desired PCR product is detected. Probe-based detection still requires high PCR specificity to prevent amplification artifacts such as non-specific PCR products and primer–dimers that can compete for reaction components and compromise performance. However, we’ve already optimized the QuantiNova LNA Probe PCR system for you to eliminate non-specific amplification and give you accurate and sensitive detection every time.

Most comprehensive and specific coverage

QuantiNova LNA Probe PCR lncRNA Focus Panels include the assays needed for a thoroughly researched panel of relevant pathway- or disease-focused long noncoding RNAs. The predesigned assays have been designed using our proprietary algorithm to provide the most sensitive, accurate and effective analysis and are transcript specific, enabling discrimination of closely related transcripts.

Flexible layout and controls

QuantiNova LNA Probe PCR lncRNA Focus Panels are available in 96-well plate, 384-well plate and 100-well disc formats and are used to monitor the expression of 84 lncRNAs related to a disease state or pathway, plus multiple reference genes. Each lncRNA Focus Panel includes control elements for the following:

  • Data normalization
  • Genomic DNA contamination detection
  • RNA sample quality
  • General PCR performance
Multiple plate discounts
Plate quantity ordered Discount (%)
1–5 0
6–11 25
12–23 40
24+ 55
Complimentary data analysis

The complimentary, web-based data analysis tool in the GeneGlobe Data Analysis Center includes a user-friendly wizard to guide you step-by-step through the normalization and analysis of your data and generates publication-ready results figures.

Procedure

Choose one- or two-step qRT-PCR

QuantiNova LNA Probe PCR lncRNA Focus Panels have been optimized using the time-tested and high-performance QuantiNova chemistry. Best results are obtained when reverse transcription is performed with the QuantiNova Reverse Transcription Kit. The resulting cDNA is then quantified by qPCR using the master mixes of the QuantiNova Probe PCR Kit combined with the assays on your panel.

For one-step qRT-PCR, we recommend using the QuantiNova Probe RT-PCR Kit, which offers quick reaction setup without need for optimization of reaction conditions. Simply combine RNA template with the ready-to-use RT-PCR master mix and the assays on your panel and start the reaction.

Fast and easy workflow

The fast and easy workflow can be completed in under 2 hours with minimal hands-on time and can be automated to save even more time and labor. The simple protocol has been tested for compatibility on all major brand qPCR cyclers (see figure  QuantiNova LNA Probe PCR Assays deliver consistent performance across all thermal cycler instruments). Furthermore, the cDNA generated in the RT step can be used across the entire QuantiNova LNA Probe PCR System, allowing seamless transition from assays to panels depending on your research needs, saving you time and sample.

What you need to get started with the QuantiNova LNA Probe PCR system

Reverse transcription: QuantiNova Reverse Transcription Kit

qPCR mastermix: QuantiNova Probe PCR Kit

One-Step qRT-PCR (optional): QuantiNova Probe RT-PCR Kit

Assays or panels:

  • QuantiNova LNA Probe PCR Assays
  • QuantiNova LNA Probe PCR Reference Assays
  • QuantiNova LNA Probe PCR Custom Assays
  • QuantiNova LNA Probe PCR Focus Panels
  • QuantiNova LNA Probe PCR lncRNA Focus Panels
  • QuantiNova LNA Probe PCR Custom Panels
  • QuantiNova LNA Probe PCR Flexible Panels
See figures

Applications

QuantiNova LNA Probe PCR lncRNA Focus Panels are highly suited for applications including:

  • lncRNA expression analysis, profiling and quantification
  • Validation of RNA-seq gene expression data
  • Gene expression profiling
  • Signal and pathway analysis
  • Confirming lncRNA expression knockdown by LNA GapmeRs or siRNAs
  • Biomarker development, including screening, identification and validation of disease-associated biomarkers
  • Monitoring phenotypic changes related to gene expression

Supporting data and figures

Resources

Kit Handbooks (1)
QuantiNova LNA Probe PCR Handbook
Quick-Start Protocols (1)
Safety Data Sheets (1)
Download Safety Data Sheets for QIAGEN product components.
Certificates of Analysis (1)