QIAseq Targeted DNA Extended Panels

Digital DNA sequencing to confidently detect low-frequency variants

S_1084_5_GEN_V2
Configure at GeneGlobe
Find or custom design the right target-specific assays and panels to research your biological targets of interest.

QIAseq Targeted DNA Extended Panel (96)

Cat no. / ID.   333545

Kit containing ALL reagents (except indexes) for targeted DNA sequencing; Extended panel for 96 samples
Configure at GeneGlobe To see pricing
This product contains substances regulated under REACH (EC 1907/2006 Annex XIV). The use of this product in the EU is permitted subject to an exemption (Article 56(3)). Please refer to the REACH notification and the SDS of this product, both of which can be found in the “Resources” section of this page, for more information.
QIAseq Targeted DNA Extended Panels are intended for molecular biology applications. These products are not intended for the diagnosis, prevention, or treatment of a disease.
Configure at GeneGlobe
Find or custom design the right target-specific assays and panels to research your biological targets of interest.

Features

  • Digital sequencing enabled by molecular barcodes to remove PCR duplicates
  • Complete Sample to Insight solution streamlines the workflow
  • Compatibility with low-quality DNA enables efficient sequencing of FFPE and cfDNA samples
  • Minimal DNA input to preserve precious samples
  • Optimized buffers and conditions to achieve high coverage of GC-rich regions
  • Add up to 100 primers to extend the content of a cataloged panel

Product Details

The QIAseq Targeted DNA Panels have been developed as a complete Sample to Insight solution to enable digital DNA sequencing by utilizing molecular barcodes. Digital DNA sequencing is a unique approach to detect low-frequency variants with high confidence by overcoming the issues of PCR duplicates, false positives and library bias.Each panel is a one-box, NGS platform-agnostic solution that contains all the necessary components to construct libraries from enriched genomic targets. Primer design is based on QIAseq Enrichment Technology, in which each genomic target is enriched by one target-specific primer and one universal primer – a strategy that removes conventional two target-specific primer design restriction and reduces the amount of required primers. All primers required for a panel are pooled into an individual primer pool to reduce panel handling and the number of pools required for enrichment and library construction. Platform-specific indexes, which are contained in a separate box, allow the multiplexing of up to 384 samples per sequencing run. The unique buffer and enzyme system used in the QIAseq targeted DNA panels has been optimized to achieve high coverage of GC-rich genomic regions.

Extended panels allow you to extend the content of any of the cataloged panels by adding up to 100 new primers. The new primers will be added to the content of the cataloged panel.

Need a quote for your research project or would you like to discuss your project with our specialist team? Contact Us

Performance

  • Accuracy: Innovative digital sequencing (incorporating molecular barcodes) eliminates PCR duplication and amplification artifacts to detect low-frequency variants with high confidence.
  • Specificity: The unique combination of our proprietary primer design algorithm and rigorous testing of every primer assay guarantees high specificity and accurate results.
  • Uniformity: The QIAseq Targeted DNA Panel workflow has been optimized to deliver highly uniform sequencing results, to ensure sequencing capacity is utilized very efficiently.
  • Sensitivity: Digital DNA sequencing approach is optimized to deliver high confidence in calling low-frequency DNA variants. Over 90% sensitivity for 1% NA12878 SNP and indel on typical coding region with false positive less than 15 per mega base region when variants are detected with tiled primer design to cover complete coding region of each gene.
  • Universality: The chemistry used in the QIAseq Targeted DNA Panels and workflow is compatible with both regular and GC-rich genomic regions, allowing one to achieve 100% coverage of genes rich in GC content such as CEBPA and CCND1.
  • Flexibility: The QIAseq targeted DNA panels offer a high degree of flexibility in content and sample multiplexing. Several cataloged panels have been developed for a wide range of applications. One can also build a custom panel for a specific content, or extend the contents of an existing cataloged panel. Up to 384 samples can be multiplexed using the QIAseq indexes.

Principle

PCR duplicates are a major issue in targeted DNA sequencing, since, through PCR amplification, they turn unique DNA molecules into identical DNA molecules that cannot be distinguished from each other. In addition, errors from PCR amplification and sequencing process may also be present in final reads that lead to false positive variants in sequencing results. This, in turn, results in the inability to confidently call DNA variants present at low frequencies in the starting DNA material. To overcome the issue of PCR duplicates and amplification artifacts, the QIAseq Targeted DNA Panels use digital sequencing by incorporating molecular barcodes into the starting DNA material before any amplification takes place, thereby preserving the uniqueness of the starting DNA molecules and overcoming the issues of PCR duplicates, false positives and library bias.

Procedure

The entire workflow of the QIAseq Targeted DNA Panels to go from extracted DNA to sequencing-ready libraries can be completed in 9 hours. Extracted DNA is fragmented, genomic targets are molecularly barcoded and enriched, and libraries are constructed. Sequencing files can be fed into the QIAseq pipeline, a cloud-based data analysis pipeline, which will filter, map and align reads, as well as count unique molecular barcodes associated with targeted genomic regions, and call variants with a barcode-aware algorithm. This data can then be fed into IVA or QCI for interpretation.

Applications

The QIAseq Targeted DNA Extended Panels can be used to call a variety of DNA variants from a wide range of sample types for numerous applications.

DNA variants:

  • SNVs
  • Small indels
  • CNVs

Sample types:

  • FFPE
  • Plasma/serum
  • Fresh or frozen tissue
  • Cell lines

Applications:

  • Profiling of DNA variants in solid and hematologic malignancies
  • Hotspot detection in solid tumors
  • Examination of variants in mitochondrial DNA
  • Pain and ADME Pharmacogenomics
  • Human identity and paternity testing
  • Assessment of germline mutations for inherited diseases
  • Profiling of all exonic bases in BRCA 1 and BRCA2

Supporting data and figures

Resources

Application Notes (1)
Safety Data Sheets (1)
Download Safety Data Sheets for QIAGEN product components.
Certificates of Analysis (1)
よく一緒に購入される商品
RNeasy Mini Kit (50)
Cat no. / ID. 74104
RNeasy Mini Kit (50)
50 RNeasy Mini Spin Columns, Collection Tubes (1.5 ml and 2 ml), RNase-free Reagents and Buffers
£347.00
RNeasy Mini Kit (250)
Cat no. / ID. 74106
RNeasy Mini Kit (250)
250 RNeasy Mini Spin Columns, Collection Tubes (1.5 ml and 2 ml), RNase-free Reagents and Buffers.
£1,529.00
RNase-Free DNase Set (50)
Cat no. / ID. 79254
RNase-Free DNase Set (50)
1500 Kunitz units RNase-free DNase I, RNase-free Buffer RDD, and RNase-free water for 50 RNA minipreps
£86.40
DNeasy Blood & Tissue Kit (250)
Cat no. / ID. 69506
DNeasy Blood & Tissue Kit (250)
250 DNeasy Mini Spin Columns, Proteinase K, Buffers, Collection Tubes (2 ml)
£985.00
DNeasy Blood & Tissue Kit (50)
Cat no. / ID. 69504
DNeasy Blood & Tissue Kit (50)
50 DNeasy Mini Spin Columns, Proteinase K, Buffers, Collection Tubes (2 ml)
£218.00
QIAprep Spin Miniprep Kit (250)
Cat no. / ID. 27106
QIAprep Spin Miniprep Kit (250)
For 250 high-purity plasmid minipreps: 250 QIAprep 2.0 Spin Columns, Reagents, Buffers, Collection Tubes (2 ml)
£399.00
RNeasy Micro Kit (50)
Cat no. / ID. 74004
RNeasy Micro Kit (50)
50 RNeasy MinElute Spin Columns, Collection Tubes (1.5 ml and 2 ml), RNase-free DNase I, Carrier RNA, RNase-free Reagents and Buffers
£538.00
RNase-Free DNase Set (250)
Cat no. / ID. 79256
RNase-Free DNase Set (250)
5 x 1500 Kunitz units RNase-free DNase I, RNase-free Buffer RDD, and RNase-free water for 250 RNA minipreps
£388.00
QIAamp DNA Mini Kit (50)
Cat no. / ID. 51304
QIAamp DNA Mini Kit (50)
For 50 DNA preps: 50 QIAamp Mini Spin Columns, QIAGEN Proteinase K, Reagents, Buffers, Collection Tubes (2 mL)
£222.00
QFT-Plus Blood Collection Tubes (200)
Cat no. / ID. 622526
QFT-Plus Blood Collection Tubes (200)
QFT-Plus Blood Collection Tubes: Nil, TB1, TB2, and Mitogen tubes (50 each)
£997.00
QIAamp DNA Mini Kit (250)
Cat no. / ID. 51306
QIAamp DNA Mini Kit (250)
For 250 DNA preps: 250 QIAamp Mini Spin Columns, QIAGEN Proteinase K, Reagents, Buffers, Collection Tubes (2 ml)
£906.00
QFT-Plus Blood Collection Tubes Single Patient Pack (10 tests)
Cat no. / ID. 622222
QFT-Plus Blood Collection Tubes Single Patient Pack (10 tests)
10 QFT-Plus Blood Collection Tubes packs, each including: Nil, TB1, TB2, and Mitogen tubes
£211.00
RNeasy Plus Mini Kit (50)
Cat no. / ID. 74134
RNeasy Plus Mini Kit (50)
For 50 minipreps: RNeasy Mini Spin Columns, gDNA Eliminator Spin Columns, Collection Tubes, RNase-Free Water and Buffers
£384.00
Filter-Tips, 1500 µl, Qsym SP (1024)
Cat no. / ID. 997024
Filter-Tips, 1500 µl, Qsym SP (1024)
Disposable Filter-Tips, racked; (8 x 128). For use with the QIAsymphony SP/AS instruments
£103.00
QIAquick PCR Purification Kit (250)
Cat no. / ID. 28106
QIAquick PCR Purification Kit (250)
For purification of 250 PCR reactions: 250 QIAquick Spin Columns, Buffers, Collection Tubes (2 ml)
£462.00
QIAquick PCR Purification Kit (50)
Cat no. / ID. 28104
QIAquick PCR Purification Kit (50)
For purification of 50 PCR reactions:50 QIAquick Spin Columns, Buffers, Collection Tubes (2 ml)
£105.00
DNeasy PowerSoil Pro Kit (250)
DNeasy PowerSoil Pro Kit (250)
For the isolation of microbial genomic DNA from all soil types.
£1,624.00
RNase A (17,500 U)
Cat no. / ID. 19101
RNase A (17,500 U)
2.5 ml (100 mg/ml; 7000 units/ml, solution) Unit definition: That amount of enzyme causing the hydrolysis of RNA at a rate such that k (velocity constant) equals unity (Kunitz units) at 25°C and pH 5.0.
£269.00