TissueLyser Adapter Sets

TissueLyser IIで、48または192サンプルの同時サンプル破砕用

S_1084_5_GEN_disclaimer

✓ 24/7 automatic processing of online orders

✓ Knowledgeable and professional Product & Technical Support

✓ Fast and reliable (re)-ordering

TissueLyser Adapter Set 2 x 24

Cat. No. / ID:  69982

Two sets of adapter plates and 2 racks for use with 2 ml microcentrifuge tubes on the TissueLyser II
Copy order details
¥90,500
AccessoriesProduct
TissueLyser Adapter Set
Tube Adapter Set
Plate Adapter Set
Tube Holder Set
For
Microcentrifuge tubes
Collection microtubes and caps

✓ 24/7 automatic processing of online orders

✓ Knowledgeable and professional Product & Technical Support

✓ Fast and reliable (re)-ordering

Product Details

TissueLyser アダプターセットは、TissueLyser II で同時に、最大48または192サンプルを効率的かつ簡便にサンプル破砕するようにデザインされています。TissueLyser Adapter Set には、24本のサンプルチューブを保持できるホルダーが2つ含まれます。本ホルダーには、2 ml のマイクロ遠心チューブが最大24本保持することができます。本ホルダーには、セーフロックチューブの使用をおすすめします。TissueLyser Adapter Set には、QIAGEN Collection Microtubes(ラック入り)とCollection Microtube Caps を使用して、最大96サンプル x 2 でサンプル破砕をすることができます。Collection Microtubes の容量は 1.2 ml です。

Resources

Supplementary Protocols (3)
Up to 1 x 109 bacteria are disrupted and homogenized by bead-milling in a guanidine-thiocyanate-containing lysis buffer. After addition of ethanol, the sample is loaded onto an RNeasy Mini spin column. Total RNA binds to the RNeasy silica-membrane, contaminants are efficiently washed away, and high-quality RNA is eluted in RNase-free water.
キットハンドブック (2)
For high-throughput disruption of biological samples
For efficient disruption of up to 48 or 192 samples in parallel on the TissueLyser
Certificates of Analysis (1)
Kit Handbooks (2)
For efficient disruption of up to 48 or 192 samples in parallel on the TissueLyser
For high-throughput disruption of biological samples

FAQ

Can I precool the TissueLyser 2 x 24 Adapter Set or the 2 x 96 Adapter Set using liquid nitrogen?

We do not recommend using the adapters of the TissueLyser II with liquid nitrogen. Instead, the adapters can be precooled at –80°C, either in the freezer or on dry ice.

FAQ ID -9173
What tubes can be used with TissueLyser Adapter Set 2 x 96 (cat. no. 69984)?

TissueLyser Adapter Set 2 x 96 should be used with Collection Microtubes (racked) and Collection Microtube Caps (cat. nos. 19560 and 19566 respectively).

FAQ ID -3086
Do you have a protocol for purification of total RNA from fatty tissues using QIAzol Lysis Reagent and MaXtract High Density?

Yes, we have the following protocols:

  • Purification of total RNA from fatty tissues using QIAzol Lysis Reagent, MaXtract High Density, and the TissueRuptor (RY29).
  • Purification of total RNA from fatty tissues using QIAzol Lysis Reagent, MaXtract High Density, and the TissueLyser (RY30).
  • Purification of total RNA from fatty tissues using the RNeasy Lipid Tissue Mini Kit and MaXtract High Density (RY31).
FAQ ID -1550
What is the maximum amount of tissue that can be disrupted using the 2 x 24 TissueLyser Adapter Set (cat. no. 69982)?

100 mg tissue per sample tube is the maximum amount we recommend when using the 2 x 24 Adapter Set. Larger amounts of tissue would require considered optimization, depending on the tissue type and condition.

When using 100 mg tissue, for best homogenization results, we recommend cutting the sample into 2 pieces of approximately 50 mg each prior to disruption and performing disruption twice, each time at 25 Hz for 5 min.

FAQ ID -9178