QuantiFast Probe PCR Kits deliver highly sensitive results, outperforming other real-time PCR kits (see table "Sensitive two-step RT-PCR on the iCycler iQ" and figure and Sensitive two-step RT-PCR). PCR run times are reduced by up to 60% (see figure " Significantly reduced PCR times"), allowing you to achieve fast PCR results without compromising on PCR performance (see figure " Faster results without compromising sensitivity"). You can also greatly increase your sample throughput or efficiently share a cycler with other users.
Mean CT value | ||
Human leukocyte cDNA (ng) | QuantiFast Probe PCR +ROX Vial Kit | Kit from Supplier BV |
100 | 29.13 | 31.13 |
10 | 32.50 | 34.43 |
1 | 36.15 | 40.00 |
No template control | 40.00 | 40.00 |
QuantiFast Probe PCR Kits allow accurate quantification over a wide dynamic range (see figure " Wide dynamic range and high sensitivity"). Template dilutions of up to 7 logs can be reliably detected (see table "Detection over 7 logs of template in two-step RT-PCR on the LightCycler 2.0 " and figure " Detection over 7 logs of template").
Mean CT value | ||
Human leukocyte cDNA | QuantiFast Probe PCR +ROX Vial Kit | Kit from Supplier R |
---|---|---|
100 ng | 11.99 | 14.56 |
10 ng | 15.54 | 17.99 |
1 ng | 19.22 | 22.16 |
100 pg | 22.63 | 25.14 |
10 pg | 26.43 | 30.15 |
1 pg | 30.02 | 34.43 |
100 fg | 33.42 | 37.10 |
No template control | 40 | 40.00 |
PCR efficiency | 90% | 80.1% |
QuantiFast Probe PCR Kits deliver highly sensitive and rapid results over a wide dynamic range on both standard and fast cyclers. The kits are designed for use with all types of sequence-specific probes, including hydrolysis probe detection (e.g., TaqMan and other dual-labeled probes) and FRET probes. A specially developed, fast PCR buffer contains the novel additive Q-Bond, which significantly reduces denaturation, annealing, and extension times (see figure " Fast primer annealing"). The buffer also contains a balanced combination of K+ and NH4+ ions, which promote specific primer annealing, enabling high PCR specificity and sensitivity (see figure " Specific primer annealing"). In addition, HotStarTaq Plus DNA Polymerase provides a stringent hot start, preventing the formation of nonspecific products.
Component | Features and benefits | Benefits |
---|---|---|
HotStarTaq Plus DNA Polymerase | 3 min activation at 95ºC | Set up of qPCR reactions at room temperature |
QuantiFast Probe PCR Buffer | Balanced combination of NH4+ and K+ ions | Specific primer annealing ensures reliable PCR results |
Unique Q-Bond additive | Faster PCR run times, enabling faster results and more reactions per day | |
ROX dye† | Normalizes fluorescent signals on Applied Biosystems and, optionally, Agilent instruments | Precise quantification on cyclers that require ROX dye. Does not interfere with PCR on any real-time cycler |
QuantiFast Probe PCR Kits contain ready-to-use master mixes that eliminate the need for optimization of reaction and cycling conditions. Simply add template DNA, primers, and probe to the master mix and follow the protocol in the handbook to get fast and reliable results on any real-time cycler. Kits are available with or without ROX passive reference dye in the master mix, enabling use on virtually any real-time cycler (see table). Due to the optimized ROX concentrations, detection of even low copy numbers is achieved through automatic data analysis.
ROX dye | Kit | Compatible cyclers |
---|---|---|
Supplied in master mix | QuantiFast Probe PCR Kit | All cyclers from Applied Biosystems except Applied Biosystems 7500 |
Supplied in a separate tube | QuantiFast Probe PCR +ROX Vial Kit | Applied Biosystems 7500, and cyclers from Agilent, Bio-Rad, Cepheid, QIAGEN, Eppendorf, Roche, and other suppliers |
For optimal results in real-time two-step RT-PCR, we recommend synthesizing cDNA using the QuantiTect Reverse Transcription Kit. The kit provides fast cDNA synthesis in just 20 minutes with integrated removal of genomic DNA contamination.
QuantiFast Probe Assays are predesigned, genomewide assays that use hydrolysis, probe-based detection. They are delivered with the QuantiFast Probe PCR Kit for guaranteed results in singleplex, two-step qRT-PCR.
QuantiFast Probe PCR Kits can be used for probe-based gene expression analysis of cDNA targets and quantitative gDNA analysis on any real-time cycler. This includes instruments from Applied Biosystems, Bio-Rad, Cepheid, Eppendorf, Roche, and Agilent. For the Rotor-Gene Q and other Rotor-Gene cyclers, we recommend using the Rotor-Gene Probe PCR Kit, which has been specially developed for fast cycling on these instruments.
Features | Specifications |
---|---|
ApplicationsKO | Probe-based, real-time PCR, two-step RT-PCR |
Sample/target type | cDNA, DNA |
Real-time or endpoint | Real-time |
Reaction type | Real-time and two-step RT-PCR |
Single or multiplex | Single |
With or without ROX | Available with ROX in master mix and with ROX as separate vial |
SYBR Green I or sequence-specific probes | Sequence-specific probes |
Thermal cycler | All real-time cyclers (e.g. Roche LightCycler®, Corbett Rotor-Gene, Applied Biosystems) |