EZ1 DSP DNA Blood Kit

For automated purification of DNA from 1–24 or 1–14 human biological specimens using the EZ2 Connect MDx or the EZ1 Advanced XL

S_1084_5_GEN_V2

✓ 24/7 automatic processing of online orders

✓ Knowledgeable and professional Product & Technical Support

✓ Fast and reliable (re)-ordering

EZ1 DSP DNA Blood Kit (48)

Cat. No. / ID:   62124

For 48 DNA preps: Prefilled Reagent Cartridges, Disposable Tip-Holders, Disposable Filter-Tips, Sample Tubes, Elution Tubes
PLN 3,248.00
Log in To see your account pricing.
The EZ1 DSP DNA Blood Kit is intended for in vitro diagnostic use.

✓ 24/7 automatic processing of online orders

✓ Knowledgeable and professional Product & Technical Support

✓ Fast and reliable (re)-ordering

Features

  • For in vitro diagnostic use
  • Rapid purification of high-quality DNA from whole blood samples
  • Straightforward and easy automated purification on the EZ2 Connect MDx
  • Standardized processing ensures reproducible results

Product Details

The EZ1 DSP DNA Blood Kit contains all required reagents and labware for automated purification of DNA from 200 or 350 µl human whole blood using magnetic particle technology. Reagents are supplied in prefilled reagent cartridges, which ensures speed and convenience in loading the EZ1 Advanced, the the EZ1 Advanced XL. or the EZ2 Connect MDx . The CE-IVD-marked system provides exact performance specifications, assuring highly reliable DNA purification.

Performance

Efficient purification of genomic DNA

Automated DNA purification provides high levels of reliability and standardization and helps to eliminate variation caused by handling errors. The EZ1 Advanced XL or the EZ2 Connect MDx in combination with the EZ1 DSP DNA Blood Kit enables efficient purification of genomic DNA from human whole blood.

 

Principle

Automated sample preparation enables efficient, standardized purification of nucleic acids. The EZ2 Connect MDx and the EZ1 Advanced XL enable purification of nucleic acids using proven magnetic-particle technology for use in routine in vitro diagnostic applications. Reagent production is subjected to stringent quality control assuring reliable and robust performance. An easy-to-use instrument, prefilled and sealed reagent cartridges, and simple protocol selection and worktable setup help to prevent handling errors and allow the system to be operated by anyone — from the novice to the expert. Manual handling of potentially infectious samples is minimized, ensuring safety to the user and reliable processing of samples. Purified genomic DNA is ready to use in sensitive downstream diagnostic assays, such as PCR.

Procedure

The EZ2 Connect MDx or the EZ1 Advanced XL in combination with the proven EZ1 DSP DNA Blood Kit enables purification of DNA from 1–24 samples (EZ2 Connect MDx) or 1-14 samples (EZ1 Advanced XL) of human whole blood. All processing steps are performed by the instrument, from piercing the reagent cartridge to elution of highly pure nucleic acids. The innovative design of the instrument means that the pipet tips function as separation chambers, increasing the efficiency of magnetic purification and eliminating the need for centrifugation steps. The streamlined procedure provides robust walkaway purification of nucleic acids with minimal hands-on time.

Applications

With the EZ2 Connect MDx or the combination of the EZ1 Advanced XL DSP DNA Blood Card and the EZ1 Advanced XL, the EZ1 DSP DNA Blood Kit provides a fully automated procedure for purification of DNA from human whole blood. Genomic DNA purified using the EZ1 DSP DNA Blood Kit is ready to use in downstream diagnostic assays.

Specifications

FeaturesSpecifications
ApplicationsDownstream detection procedures in molecular diagnostics, such as PCR
CE/FDA/IVD compatibleCE/IVD
ProcessingAutomated
Purification of total RNA, miRNA, poly A+ mRNA, DNA or proteinGenomic DNA
Elution volume50–200 µl
TechnologyMagnetic particles
For automated processingEZ2 Connect MDx and EZ1 Advanced XL
Main sample typeWhole blood
Sample amount200 µl or 350 µl
YieldVaries on WBC count, please see handbook

FAQ

How long can eluates be stored after sample preparation using the BioRobot EZ1 DSP instrument?
Eluates can be stored for up to 10 weeks at 2-8°C; up to one year either at -20°C or at -80°C without any loss of performance.
FAQ ID -1569
What do I have to do if precipitates are visible in the lysis buffer (well 1 of the reagent cartridge [RCB])?
Place the reagent cartridges (RCB) into a shaker–incubator, and incubate at 30–40°C with mild agitation for up to 2 hours. Do not use the reagent cartridges (RCB) if the precipitates do not redissolve.
FAQ ID -1568
Can samples other than whole blood be used with the EZ1 DSP DNA Blood Kit?
No. The EZ1 DSP DNA Blood system is a generic system that uses magnetic-particle technology for automated isolation and purification of genomic DNA from human whole blood samples, for in vitro diagnostic purposes. The system is not for use with tissue or stool samples. It is also not for isolation or purification of bacterial, fungal, viral, or parasite nucleic acids, nor for isolation or purification of RNA. The system performance has not been evaluated for isolation or purification of genomic DNA from buffy coat, cultured or isolated cells, swabs, dried blood spots, or cell-free body fluids, such as liquor, plasma, serum, or urine. Contact your local QIAGEN representative for information about other EZ1 Kits.
FAQ ID -1564
How long can blood samples be stored before sample preparation using the EZ1 DSP DNA Blood system?
We recommend using fresh blood samples. Storage of samples for up to 3 days at 25°C leads to significant reduction in DNA yield and integrity. For long-term storage, store blood samples at -70°C. This helps to minimize the reduction in yield and integrity due to DNA degradation that occurs following storage at room temperature (15-25°C) or at 2-8°C. However, no negative effect on PCR was observed by storage at room temperature, 2-8°C, -70°C.
FAQ ID -1565
Can I use sample preparation cartridges from other suppliers together with the BioRobot EZ1 DSP instrument?
No. The BioRobot EZ1 DSP instrument is intended to be used only with QIAGEN sample preparation cartridges.
FAQ ID -1567
How can I track samples during collection, sample preparation, and downstream assay?
A sample sheet template is included in the handbook. This sample sheet may be useful for recordkeeping when using the EZ1 DSP DNA Blood or the EZ1 DSP Virus procedure. This sheet can be photocopied and labeled with descriptions of the samples and details of the run.
FAQ ID -1570