QIAseq Targeted RNA-seq Panel for T-cell Receptor

For RNA-seq library construction of T-cell receptor (TCR) alpha, beta, gamma and delta genes using 200 pg to 1000 ng of RNA from human or mouse samples.

S_1321_4_LS_GG_QIAseq_Targeted_RNA_Panel_Human_TCR_12

✓ 24/7 automatic processing of online orders

✓ Knowledgeable and professional Product & Technical Support

✓ Fast and reliable (re)-ordering

QIAseq Targeted RNA Panel Human TCR (12)

Cat. No. / ID:   334651

Includes enzymes, buffers and TCR-alpha, TCR-beta, TCR-gamma and TCR-delta panels
SEK 9,345.00
Log in To see your account pricing.
KitIndex
T-cell Receptor Library Kit
T-cell Receptor Index Kit
Sample type
Human
Mouse
Samples
12
96
Must use 334792 QIAseq 24-Index TCR UDI (24) or 334805 QIAseq 96-Index TCR UDI Set A (96) to complete library construction
The QIAseq Targeted RNA Panel Human TCR (12) is intended for molecular biology applications. This product is not intended for the diagnosis, prevention, or treatment of a disease.
Notice: The QIAseq Targeted RNAseq Panel for T-cell Receptor is an upgraded kit and replaces the QIAseq Immune Repertoire RNA Library Kit (cat. no. 333705).
The QIAseq Targeted RNA-seq Panel for T-cell Receptor is intended for molecular biology applications. This product is not intended for the diagnosis, prevention, or treatment of a disease.

✓ 24/7 automatic processing of online orders

✓ Knowledgeable and professional Product & Technical Support

✓ Fast and reliable (re)-ordering

Features

  • Unique molecular indexing (UMI) technology removes amplification, duplication and sequencing artifacts to increase accuracy
  • Profile single TCR receptors (TCR-alpha, TCR-beta, TCR-gamma, TCR-delta) or combine panels for a comprehensive immune repertoire
  • Single-tube library construction and versatile panels allow analysis of one, two, three or all four receptors at once
  • Unique dual indexing (UDI) minimizes sample index misassignment
  • Includes access to GeneGlobe Analyze for data analysis, including read alignment and clonotype report

 

Product Details

The QIAseq Targeted RNAseq Panel for T-cell Receptor enables targeted next-generation sequencing (NGS) of the human or mouse expressed T-cell receptor (TCR), which includes four distinct genes: TCR-alpha, TCR-beta, TCR-gamma and TCR-delta. This highly optimized solution incorporates unique molecular indices (UMIs) to facilitate ultrasensitive and accurate characterization of the immune repertoire in cells and tissues starting from 200 pg to 1000 ng of total RNA.

The adaptive immune system is composed of T and B lymphocytes that bind antigens via highly specific T-cell receptors (TCRs) and B cell receptors (BCRs) on their cell surfaces. To recognize a nearly infinite number of potential antigens, extensive sequence diversity of TCRs and BCRs is generated by somatic V(D)J recombination of the TCR and BCR loci, and by subsequent somatic hypermutation and class switch recombination of the BCR upon antigen stimulation. Accurate characterization of the TCR and BCR repertoires is key to understanding adaptive immune responses and has many applications across different fields, including vaccine development, autoimmunity, monitoring treatment response in lymphoid malignancies and immunotherapy.


Compared to traditional methods, NGS provides an unprecedented, high-resolution picture of the immune repertoire. However, many available immune repertoire sequencing methods involve multiplex PCR with primers targeting different V or J regions, which can introduce substantial amplification bias.


The QIAseq Targeted RNAseq Panel for T-cell Receptor utilizes unique molecular indices (UMIs) with QIAseq Enrichment Technology to robustly create targeted RNA-seq libraries for NGS instruments. This library construction approach greatly improves amplification uniformity compared to multiplexed PCR-based V and J primer pools. The incorporation of UMIs before the amplification step further reduces amplification bias and allows for accurate and sensitive TCR clonotype and repertoire diversity assessment.

The QIAseq Targeted RNAseq Panel for T-cell Receptor is a complete Sample to Insight solution for precise characterization of the TCR immune repertoire using NGS. The purchase of the TCR Panel includes access to GeneGlobe Analyze, which contains a highly optimized pipeline for read mapping and clonotype calling. 

 

 

Principle

The QIAseq Targeted RNAseq Panel for T-cell Receptor provides accurate and sensitive TCR clonotype and diversity assessment using QIAGEN Enrichment Technology. TCR-specific primers for reverse transcription and enrichment are provided along with all the necessary library construction reagents. The QIAseq Targeted RNAseq Panel for T-cell Receptor is designed to enrich TCR α, β, γ and σ subunits (individually or combined) in a single reaction using 200 pg to 1000 ng of RNA (see figure  "QIAseq Targeted RNAseq Panel for T-cell Receptor workflow").

 

See figures

Procedure

cDNA synthesis

Start with total RNA from peripheral blood leukocytes, whole blood, enriched T-cells or solid tumors. RNA samples are first reverse-transcribed into cDNA with gene-specific primers. Subsequently, second-strand synthesis occurs, which generates double-stranded cDNA (ds-cDNA). This ds-cDNA is then end-repaired with an A-addition in a single-tube protocol.

Unique Molecular Index (UMI) assignment

Prior to target enrichment and library amplification, each original cDNA molecule is assigned a unique molecular index (UMI) containing up to 18 bases. This is achieved by ligating a random sequence adapter containing the UMI to the ds-cDNA. Statistically, this process provides >268 million possible indices per adapter, with each DNA molecule in the sample receiving a unique UMI sequence.

Target enrichment and final library construction

Following UMI assignment, QIAseq Enrichment Technology is performed to capture TCR cDNA molecules with UMIs into the NGS library. For enrichment, ligated cDNA molecules are subjected to a TCR-specific enrichment using a TCR targeted panel. After enrichment, a universal PCR is performed to amplify the library and introduce unique dual indices. 

NGS adapter and Unique Dual Index (UDI) technologies

The QIAseq Targeted RNAseq Panel for T-cell Receptor requires the QIAseq 24-Index TCR UDI (24) (cat. no. 334792) or QIAseq 96-Index TCR UDI Set A (96) (cat. no. 334805), which contain the TUDI adapters and dual index primers. The UDI design significantly reduces the risk of index bleeding issues (“index hopping”) associated with next-generation sequencing instruments that utilize patterned flow cells. With unique dual indexing (UDI), each sample will be assigned two unique sample indices to overcome the error introduced by image analysis, sequencing error and demultiplexing, and to remove misassignment of sequencing data to the wrong samples.

Next-generation sequencing on Illumina NGS systems

The QIAseq Targeted RNAseq Panel for T-cell Receptor is compatible with Illumina NGS systems (MiSeq, NextSeq 1000/2000 and NovaSeq 6000). The best sequencing results are achieved using 500 or 600 cycle flow cells.

Data analysis

The QIAseq Immune Repertoire pipeline automatically performs all steps necessary to generate TCR diversity and clonotype reports from your raw NGS data. The QIAseq Immune Repertoire pipeline is available through cloud, desktop and server software packages. For cloud-based analysis, researchers can utilize the QIAseq section of GeneGlobe Analyze. For desktop and server support, QIAGEN Genomics Workbench can be used. 

Sample specifications
RNA types Total RNA, FFPE/fragmented RNA and enriched mRNA
Type of library Targeted RNA-seq with UMIs
Gene targets Human: TRA, TRB, TRD, TRG
Mouse: Tcra, Tcrb, Tcrd, Tcrg
Minimum concentration of RNA 40 pg/µL
Volume of RNA per reverse transcription reaction 5 µL
Total volume of cDNA reaction 6 µL
RIN requirements 1 to 10
Minimum DV 600% 30%

 

Sequencing specifications
Research goal
Sample type Survey with shallow sequencing Comprehensive with deep sequencing
Peripheral blood leukocytes: 200 pg to 1000 ng of total RNA 0.016–80 M reads 0.32–1600 M reads
Whole blood: 500 pg to 200 ng of total RNA 0.01–4 M reads 0.2–80 M reads
Tumor tissue: 100 ng to 1000 ng of total RNA 0.12–1.2 M reads 1.2–12 M reads
Purified T-cells: 10 to 10,000 cells of RNA 0.002–2 M reads 0.04–40 M reads

 

Product specifications
Supported index kits (required) 334792    QIAseq 24-Index TCR UDI (24)
334805    QIAseq 96-Index TCR UDI Set A (96)
Recommended control RNA for monitoring library performance (sold separately) QIAGEN XpressRef Universal Total RNA
Recommended library quantification kits (sold separately) QIAseq Library Quant Assay Kit
Cat. No. / ID: 333314
Online data analysis included with kit GeneGlobe Analyze
Standalone desktop data analysis (sold separately) CLC Genomics Workbench
Recommended NGS instruments Illumina MiSeq or NextSeq 1000/2000
Recommended sequencing cycles/length Paired-end, 600 cycles on Illumina NextSeq 1000/2000

Supporting data and figures

Resources

Certificates of Analysis (1)