MagAttract Viral RNA M48 Kit

从多达300 µl的血清或血浆样本中自动纯化病毒RNA

Products

MagAttract Viral RNA M48 Kit 旨在用于分子生物学应用。该产品不能用于疾病诊断、预防和治疗。
Image
MagAttract Viral RNA Kit (960)

Cat. No. / ID:  955538

Automated virus preparation on a third-party platform (KingFisher Flex). Proteinase K and buffers for offboard lysis, MagAttract Suspension G beads and buffers for onboard bind, wash and elute steps.
Copy order details
MagAttract Viral RNA Kit (960) 旨在用于分子生物学应用。该产品不能用于疾病诊断、预防和治疗。

Features

  • 快速纯化高品质的病毒RNA
  • 每批可灵活处理6–48个样本
  • 易于优化RNA的浓度

Product Details

MagAttract Viral RNA M48 Kit应用经验证的MagAttract磁珠技术,在BioRobot M48工作站上自动纯化病毒RNA。灵活的洗脱体积,易于优化病毒RNA的浓度,适合各种下游应用。在移液吸头中进行病毒RNA的纯化和磁力分离,提高了整个流程的效率。

Performance

MagAttract Viral RNA M48 Kit纯化一个样本获得的病毒RNA的量通常小于1 µg ,因而采用分光光度计很难定量。推荐使用定量扩增的方法确定RNA的产量。

Principle

MagAttract Viral RNA M48 Kit用于从血清和血浆中全自动纯化病毒RNA。MagAttract技术配合硅胶膜技术快速、高效的纯化RNA,硅胶膜覆盖在方便使用的磁珠表面。样本放在1.5 ml或2 ml的样品管中,在BioRobot M48工作站上处理。每批可处理6–48个样本,样本来源为至多300 µl的血清或血浆。纯化获得的RNA的量取决于样本类型和病毒滴度。

Procedure

MagAttract Viral RNA M48流程中,病毒RNA在离液盐中结合到含有磁珠的硅胶膜表面。随后,结合到磁珠上的病毒RNA使用2种不同的洗涤缓冲液有效洗涤。然后,使用不含RNase的洗脱液,在65ºC条件下,将高品质病毒RNA洗脱。

Applications

MagAttract Viral RNA M48 Kit和BioRobot M48工作站共同使用,纯化得到的高品质RNA适用于各种下游应用,包括:

  • 病毒流行病学和基因分型
  • 传染性疾病的研究

Supporting data and figures

Specifications

FeaturesSpecifications
ApplicationsPCR, real-time, genotyping, sequencing
Sample amount300 µl
For automated processingBioRobot M48 Workstation
Elution volume50–100 µl
Main sample typeSerum, plasma
Purification of total RNA, miRNA, poly A+ mRNA, DNA or proteinViral RNA
ProcessingAutomated
FormatFilter tip (up to 48 per run)
TechnologyMagnetic particles

Resources

试剂盒操作手册 (1)
安全数据表 (1)
Download Safety Data Sheets for QIAGEN product components.
Certificates of Analysis (1)
Kit Handbooks (1)
Safety Data Sheets (1)
Download Safety Data Sheets for QIAGEN product components.

FAQ

Where can I download the protocol for the KingFisher Flex?

You will find a link to the protocol under the Resources tab.

3798
Who can help if it is not clear if issues are caused by the third party instrument or by the chemistry?

Please contact QIAGEN Technical Services.

3802
Who can help in case of issues with the third party instrument?

Please contact the respective QIAGEN Technical Services.

3799
Is the virus inactivated during the procedure?

This cannot be proven with the methods we have at our disposal.

3800
I would like to use the kit on another third party instrument. Who should I contact?

Please contact QIAGEN Technical Services.

3803
Can I use sample volumes other than 300 µl?

Using the same protocol, 200, 300, and 400 µl can be prepared, with the expected loss or gain in sensitivity.

3801
Are protocols also available for other instruments (e.g., Hamilton Star and Tecan Fluent)?

Not yet, but these might be added here in the future. Please contact QIAGEN Technical Services.

3797