miRCURY LNA miRNA Custom PCR Panels

Custom 96- and 384-well plates of LNA-enhanced, SYBR® Green-based miRNA qPCR assays

S_1084_5_GEN_V2
Configure at GeneGlobe
Find or custom design the right target-specific assays and panels to research your biological targets of interest.

miRCURY LNA Custom PCR Panel (8)

Cat. No. / ID:   339330

8 identical, ready-to-use 96- or 384-well plates; each well contains primers sufficient for one 10 µl reaction; for SYBR® Green-based detection
Configure at GeneGlobe To see pricing
Panel
Panel
Additional Plate
Configure at GeneGlobe
miRCURY LNA miRNA Custom PCR Panels are intended for molecular biology applications. These products are not intended for the diagnosis, prevention, or treatment of a disease.
Configure at GeneGlobe
Find or custom design the right target-specific assays and panels to research your biological targets of interest.

Features

  • Combine predesigned verified and custom-designed LNA PCR Assays in single-use, ready-to-use plates
  • Customize for your favored plate type, layout, PCR instrument and batch size
  • Great for sensitive, specific and reproducible miRNA profiling of a medium to large number of samples
  • Use our new easy-to-use online design tool

Product Details

miRCURY LNA miRNA Custom Panels are ready-to-use 96- and 384-well plates containing individual miRCURY LNA miRNA PCR Assays according to your particular requirements. Both forward and reverse PCR amplification primers are miRNA-specific and are optimized with LNA technology, enabling extremely sensitive and specific miRNA quantification with the miRCURY LNA miRNA PCR System. Each well contains sufficient primer set for one 10 µl reaction.

Need a quote for your research project or would you like to discuss your project with our specialist team? Just contact us!

Performance

Top performance in specificity

The miRCURY LNA miRNA PCR System is the only miRNA quantification platform with absolute specificity (see the miRQC study published in Nature Methods) and out-performed another probe-based miRNA qPCR platform in specificity tests (see figure  Specificity test alongside competitor probe-based miRNA qPCR system). This eliminates false positives and ensures only robust and reliable miRNA signals.
The easy-to-follow, 3-hour protocol saves you both time and effort in the laboratory. Simply dilute the synthesized cDNA, combine it with the miRCURY LNA SYBR Green Master Mix and aliquot into the PCR plate, which is then ready to run in your real-time PCR instrument. The number of pipetting steps is reduced to a minimum, reducing technical variation. As a result, you can achieve extremely high reproducibility from day-to-day and even site-to-site (see figures  Excellent day-to-day reproducibility and  Excellent site-to-site correlation). High reproducibility is even possible when profiling difficult samples, such as RNA purified from serum (see figure  Excellent reproducibility between RT reactions on total RNA from serum).

See figures

Principle

Design your own 96- or 384-well miRNA qPCR plates based on a fully flexible layout and several convenient, predefined layouts. Place predesigned miRCURY LNA miRNA PCR Assays or your own Custom miRCURY PCR Assays into the panel using an intuitive and easy-to-use online plate configurator. The panels are delivered ready-to-use, with one single assay per well for a 10 µl reaction volume. Just add cDNA and miRCURY LNA SYBR Green Master Mix.
Coverage
Custom miRNA PCR Panels are available in 2 different formats:
  • 96-well, ready-to-use: design your panels from one of three available layouts. Choose from our vast selection of experimentally validated LNA miRNA PCR primer sets and reference gene primer sets for human, mouse and rat miRNA quantification.
  • 384-well, ready-to-use: design your panels from one of four available layouts. Choose from our vast selection of experimentally validated LNA miRNA PCR primer sets and reference gene primer sets for human, mouse and rat miRNA quantification.

Custom miRNA PCR Panels come with a pre-positioned interplate calibrator (IPC) in replicates that allow optimal calibration and control assessment in multi-plate studies. The IPC is mandatory but can be re-positioned to suit your preferred plate layout. In additional, the panel is displayed with one or more pre-positioned UniSp6 RNA Spike-in controls (CP). RNA spike-in controls may be used for monitoring the cDNA synthesis or RNA purification. The UniSp6 CP assay can be removed and substituted by miRNA primer set(s) or other RNA spike-in control assays. Alternative RNA spike-in controls include UniSp2, UniSp4, UniSp5 and cel-miR-39-3p.
Add custom assays
It is now possible to add custom assays to your custom plate. Custom assays are designed through one of our custom assay design tools. Design LNA-enhanced PCR primers for sequences not available among our predesigned assays, e.g., for novel miRNAs identified using next-generation sequencing.

Procedure

miRNA expression profiling with miRCURY LNA miRNA PCR Panels is straightforward and robust. First, prepare cDNA using the miRCURY LNA RT Kit. Second, add a premix of cDNA, miRCURY LNA SYBR Green PCR Master Mix and RNase-free water to a miRCURY miRNA PCR Panel. Third, run the reaction in a real-time PCR cycler.

Applications

miRCURY LNA Custom PCR Panels are used as part of the miRCURY LNA miRNA PCR System for:
  • Pathway- and disease-focused miRNA profiling
  • Biomarker discovery

Supporting data and figures

Resources

Safety Data Sheets (1)
Download Safety Data Sheets for QIAGEN product components.
Scientific Posters (1)
Poster for download
Kit Handbooks (2)
For highly sensitive, real-time RT-PCR detection of miRNAs using SYBR® Green
Certificates of Analysis (1)