QIAquick Nucleotide Removal Kit

从酶促反应物中回收纯化多至10 μg寡核苷酸(17–40mers)和DNA片段(40 bp–10 kb)

S_1343_DNA_QQ0804

✓ 全天候自动处理在线订单

✓ 博学专业的产品和技术支持

✓ 快速可靠的(再)订购

QIAquick Nucleotide Removal Kit (250)

Cat. No. / ID:   28306

250 QIAquick Spin Columns, Buffers, Collection Tubes (2 ml)
SGD 759.00
登录 要查看您的账户定价。
KitColumn
QIAquick Nucleotide Removal Kit
QIAquick Spin Columns
QIAquick Nucleotide Removal Kit 旨在用于分子生物学应用。该产品不能用于疾病诊断、预防和治疗。

✓ 全天候自动处理在线订单

✓ 博学专业的产品和技术支持

✓ 快速可靠的(再)订购

特点

  • 即用型DNA回收率高达95%
  • 流程快速、方便
  • 3个简单步骤即可回收多达10 kb DNA片段
  • 包含凝胶上样染料,方便样本分析

产品详情

QIAquick Nucleotide Removal Kit提供离心柱、缓冲液和收集管,基于硅胶膜技术,纯化寡核苷酸和DNA。去除没有整合的核苷酸、盐和其他杂质。使用快速的结合、洗涤、洗脱过程使用30–50 μl洗脱体积即可纯化大于17 nt的寡核苷酸和40 bp–10 kb的DNA。该流程可在QIAcube全自动核酸纯化仪上全自动运行。

绩效

QIAquick Nucleotide Removal操作流程去除核酸、酶、盐和DNA样本中的其他杂质(参见" Complete removal of nucleotides from labeled oligos")。使用微型离心机,可以纯化17mer–10 kb的DNA。小于50 µl的样本可以使用DyeEx Spin Kit进行纯化。
查看图表

原理

QIAquick Kits提供硅胶膜装置,在高盐度缓冲液中结合DNA,低盐度缓冲液或水中洗脱DNA。纯化过程可去除引物、核苷酸、酶、矿物油、盐、琼脂糖、溴化乙锭和DNA样品中的其他杂质。硅胶膜技术解决了松散树脂的常见问题和不便,特制的结合缓冲液针对特殊应用优化,促进特定片段范围内DNA的选择性吸附。

凝胶上样染料

为实现更快、更方便的样品处理和分析,已提供胶上样染料。GelPilot Loading Dye含有3种示踪染料(二甲苯蓝、溴酚蓝和orange G)便于优化琼脂糖凝胶跑胶时间,避免小DNA片段跑得过远 (参见 " GelPilot Loading Dye")。

查看图表

程序

QIAquick系统使用简单的结合、洗涤、洗脱过程(参见" QIAquick Nucleotide Removal procedure")。结合缓冲液直接加入到样本中,然后将混合液加入到QIAquick离心柱中。在缓冲液提供的高盐度条件下,核酸吸附到硅胶膜上。洗涤杂质,使用小体积量的低盐缓冲液或水洗脱DNA,所得DNA可直接用于后续应用。

处理过程

QIAquick离心柱可提供两个方便的处理方法。离心柱可放在传统的台式微型离心机上。QIAquick Nucleotide Removal Kit以及其他的QIAGEN离心柱试剂盒可在QIAcube全自动核酸纯化仪器上全自动化运行,确保高产量和标准化的结果(参见"Spin column handling options  A, and  B")。

查看图表

应用

QIAquick系统纯化的DNA片段可直接用于各种应用,包括测序、微阵列分析、连接和转化、限制性酶切、标记和显微注射。

辅助数据和图表

Specifications

FeaturesSpecifications
Binding capacity10 µg
TechnologySilica technology
Recovery: oligonucleotides dsDNARecovery: oligonucleotides, dsDNA
FormatTube
Elution volume30–50 µl
ProcessingManual
Sample type: applicationsDNA, oligonucleotides: PCR reactions
Removal <10mers 17–40mers dye terminator proteinsRemoval <10mers
Fragment size40 bp – 10 kb

资源

快速启动实验方案 (1)
补充实验方案 (1)
QIAquick® Spin Columns can now be used on any vacuum manifold with luer connectors, for example, the QIAvac 6S or QIAvac 24 with QIAvac Luer Adapters. This protocol is designed for removal of primers <10 bases, enzymes, salts, and unincorporated nucleotides from biotin-, or DIG-labeled DNA fragments and oligonucleotides >17 nucleotides.
安全数据表 (1)
Download Safety Data Sheets for QIAGEN product components.
Certificates of Analysis (1)

FAQ

I bound an 11 kb DNA fragment to a QIAquick column; is it completely lost?

Larger DNA fragments bind more tightly to the QIAquick columns. It is difficult to predict whether a DNA fragment larger than 10 kb can be efficiently recovered, because this depends on base composition as well as fragment size. If the fragment is only a few kb larger than the 10 kb limit, it can be helpful to heat the elution buffer EB to 60°C and let it incubate on the column for a few minutes before centrifuging. However, please note that it will become less likely to recover your sample the larger the fragment size is. As we cannot guarantee recovery of fragments larger than the maximum cutoff size, we do not recommend to purify such fragments using QIAquick Kits.

The QIAEX II Kit can be used to extract DNA fragments up to 50 kb from agarose or polyacrylamide gels.

 

FAQ ID -756
Are the columns of the QIAquick PCR Purification-, Gel Extraction-, and Nucleotide Removal Kit interchangeable?
Yes - all QIAquick Spin Kits contain identical columns, but different binding buffers optimized for each specific application.
FAQ ID -577
How can I improve recoveries when using the QIAquick Kits?

Buffer PE did not contain ethanol

Ethanol must be added to Buffer PE (concentrate) before use. Repeat procedure with correctly prepared Buffer PE.

Inappropriate elution buffer

DNA will only be eluted efficiently in the presence of low-salt buffer (e.g., Buffer EB: 10 mM Tris·Cl, pH 8.5) or water. Elution efficiency is strongly dependent on the salt concentration and pH of the elution buffer. Contrary to adsorption, elution is most efficient under basic conditions and low salt concentrations. DNA is eluted with 50 or 30 µl of the provided Buffer EB (10 mM Tris·Cl, pH 8.5), or water. The maximum elution efficiency is achieved between pH 7.0 and 8.5. When using water to elute, make sure that the pH is within this range. In addition, DNA must be stored at –20°C when eluted with water since DNA may degrade in the absence of a buffering agent. Elution with TE (10 mM Tris·Cl, 1 mM EDTA, pH 8.0) is possible, but not recommended because EDTA may inhibit subsequent enzymatic reactions.

Elution buffer incorrectly dispensed

Add elution buffer to the center of the QIAquick membrane to ensure that the buffer completely covers the membrane. This is particularly important when using small elution volumes (30 µl).

FAQ ID -180
Can QIAquick Kits be used to clean up RNA samples?
Although it is possible to use the QIAquick Nucleotide Removal Kit and QIAquick PCR Purification Kit for RNA purification, the conditions are not optimized for RNA, nor are RNase-free conditions guaranteed. The RNeasy MinElute Cleanup Kit is recommended for clean-up, concentration and desalting of RNAs above 200 bases in length.
FAQ ID -490
How do I perform a DNA precipitation to concentrate my sample?
  • Add 1/10 volume of 3 M Na-Acetate pH 5.2, and 2 to 2.5 volumes of ice-cold 100% ethanol to the DNA sample
  • Mix, and store at –20°C for at least 1 h to precipitate the DNA
  • Recover the precipitated DNA by centrifugation at full speed in a microcentrifuge for 15–20 min
  • Pour off the ethanol and wash the pellet twice with room-temperature 70% ethanol
  • Allow the DNA pellet to air-dry
  • resuspend the DNA in a suitable volume of sterile TE buffer or distilled water
FAQ ID -305
Do you have a protocol for cleanup of non-radioactive DNA samples?
Yes, please follow the Supplementary Protocol 'Cleanup of nonradioactive samples using the QIAquick Nucleotide Removal Kit' (QQ04).
FAQ ID -945
Why does my DNA sample float out of the slot when loading it onto an agarose gel?

DNA fragments purified with the QIAGEN DNA Cleanup Systems, i.e., the QIAquick PCR Purification Kit, the MinElute Reaction Cleanup Kit, the QIAEX II Gel Extraction Kit etc. may float out of the loading wells of agarose gels due to residual ethanol carried over from the wash step with Buffer PE (despite the addtition of glycerol-containing loading buffer).

Use either of the following options to remove residual ethanol from the eluate:

  • re-purify the sample using a QIAquick-, or MinElute column, or QIAEX II resin
  • incubate the eluate at 56°C for 10 min to evaporate the ethanol
  • dry down the sample in a vacuum centrifuge, and resuspend the pellet in a small volume of sterile water
FAQ ID -205
Is it possible to clean up a methylation reaction containing bisulfite with QIAquick Cleanup Kits?
Yes, bisulfite containing methylation reactions can be cleaned up with our silica-based cleanup products, such as QIAquick and QIAEX II. Please see Goyon et al. (1994),  'Perpetuation of cytosine methylation in Ascobolus immersus implies a novel type of maintenance methylase', published in J Mol Biol. 1994 Jul 1;240(1):42-51, for a reference.
FAQ ID -519
Do you have information about the cleanup of single-stranded DNA (ssDNA) with QIAquick columns?

As a rule of thumb, single-stranded DNA binds to silica with approximately half the affinity of a double-stranded DNA fragment of the same length under the buffer conditions used in the QIAquick and MinElute Kits. Even though no systematic experimental data exists, we expect that recovery of ssDNA fragments of approximately 200 nucleotides and below will not be very efficient after cleanup using the QIAquick PCR Purification Kit or MinElute PCR Purification Kit. By comparison, it should be possible to purify fragments longer than 140 nucleotides using the QIAquick Gel Extraction Kit.

Note that recovery of single strand DNA is influenced to some degree also by factors such as base composition and secondary structure. It has to be determined empirically by the researcher if cleanup of single-stranded DNA with QIAquick columns yields satisfactory results.

FAQ ID -759
What is the composition of Buffer EB?

The composition of Buffer EB is:

  • 10 mM Tris-Cl, pH 8.5

Buffer EB is the elution buffer used in the QIAquick PCR, Gel Extraction, Nucleotide Removal Kits, and MinElute Kits for DNA cleanup, and the QIAprep Miniprep Kits for small-scale plasmid purification. The purified DNA can also be eluted in TE (10 mM Tris-Cl, 1 mM EDTA, pH 8.0), but the EDTA may inhibit subsequent enzymatic reactions.

FAQ ID -199
What is the small band below my fragment of interest on an agarose gel after DNA cleanup using QIAquick?

Occasionally, DNA fragments eluted from the silica matrix of QIAquick, MinElute or QIAEX II Kits will contain denatured single-stranded DNA (ssDNA), appearing as a smaller band on an analytical gel. Under certain conditions, chaotropic agents (present in all silica-based DNA purification methods) can denature DNA fragments. This is a rare event that may be influenced by sequence characteristics such as the presence of inverted repeats or A–T-rich stretches.

Because salt and buffering agents promote renaturation of DNA strands, the following tips are recommended:

  • use the eluted DNA to prepare your downstream enzymatic reaction, but omit the enzyme. Incubate the reaction mix at 95°C for 2 minutes to reanneal the ssDNA, and allow the tube to cool slowly to room temperature before adding the enzyme and proceeding
  • alternatively, the DNA can be eluted from the silica-gel membrane or resin in 10 mM Tris buffer containing 10 mM NaCl. However, the salt concentration of the eluate must then be taken into consideration in downstream applications.
FAQ ID -148
Can I buy QIAquick and MinElute columns separately?

The QIAquick Spin Columns (100) (cat. no. 28115) in the QIAquick PCR Purification, Gel Extraction, Nucleotide Removal and PCR & Gel Cleanup kits are also sold separately from the kits.

The MinElute columns in the MinElute PCR Purification, Gel Extraction and Reaction Cleanup kits are not sold separately.

We always provide extra buffers in our kits so you can scale up reactions, add extra washes or allow for spillage.

FAQ ID -2460