QIAcuity Digital PCR System

๋‚˜๋…ธํ”Œ๋ ˆ์ดํŠธ ๊ธฐ๋ฐ˜ ๋””์ง€ํ„ธ PCR ์• ํ”Œ๋ฆฌ์ผ€์ด์…˜

๊ฐ€์ƒ ๋ฐ๋ชจ
๊ฐ€์ƒ ํˆฌ์–ด๋ฅผ ํ†ตํ•ด ์ด ์ œํ’ˆ์— ๋Œ€ํ•ด ์ž์„ธํžˆ ์•Œ์•„๋ณด๊ณ  ์ž‘๋™ํ•˜๋Š” ๋ชจ์Šต์„ ํ™•์ธํ•ด ๋ณด์„ธ์š”

QIAcuity One, 2plex Device

์นดํƒˆ๋กœ๊ทธ ๋ฒˆํ˜ธ / ID.   911001

์ตœ๋Œ€ 2๊ฐ€์ง€ ํ˜•๊ด‘ ์—ผ๋ฃŒ ๊ฒ€์ถœ์šฉ 1๊ฐœ ํ”Œ๋ ˆ์ดํŠธ ๋””์ง€ํ„ธ PCR ๊ธฐ๊ธฐ, ๋กค๋Ÿฌ, USB ํ”Œ๋ž˜์‹œ ๋ฉ”๋ชจ๋ฆฌ ๋ฐ QIAcuity Software Suite: 1ํšŒ์˜ ์˜ˆ๋ฐฉ ์œ ์ง€๋ณด์ˆ˜ ๋ฐฉ๋ฌธ ํฌํ•จ. ๋˜ํ•œ ๊ณต์ž„, ์ถœ์žฅ ๋ฐ ๋ถ€ํ’ˆ 1๋…„ ๋ณด์ฆ ํฌํ•จ.
ํ˜•์‹
One
Four
Eight
๋‹ค์ค‘ ์ฑ„๋„ ๊ฒ€์ถœ
2 channels (up to 4plex)
8 channels (up to 12plex)
์„œ๋น„์Šค ์˜ต์…˜
Device
System
System FUL-2
QIAcuity๋Š” ๋ถ„์ž์ƒ๋ฌผํ•™ ๋ถ„์•ผ์— ์‚ฌ์šฉํ•˜๊ธฐ ์œ„ํ•œ ๊ฒƒ์ž…๋‹ˆ๋‹ค. ์ด ์ œํ’ˆ์€ ์งˆ๋ณ‘์˜ ์ง„๋‹จ, ์˜ˆ๋ฐฉ, ๋˜๋Š” ์น˜๋ฃŒ ๋ชฉ์ ์œผ๋กœ ์‚ฌ์šฉํ•  ์ˆ˜ ์—†์Šต๋‹ˆ๋‹ค. ๋”ฐ๋ผ์„œ ์ž„์ƒ ์‚ฌ์šฉ์„ ์œ„ํ•œ ์ œํ’ˆ์˜ ์„ฑ๋Šฅ ํŠน์ง•(์ฆ‰, ์ง„๋‹จ, ์˜ˆํ›„, ์น˜๋ฃŒ ๋˜๋Š” ํ˜ˆ์•ก์€ํ–‰)์€ ์•Œ๋ ค์ ธ ์žˆ์ง€ ์•Š์Šต๋‹ˆ๋‹ค. ๋””์ง€ํ„ธ PCR ์ง„๋‹จ ์šฉ๋„์˜ ๊ฒฝ์šฐ, QIAcuityDx Digital PCR System์„ ์‚ฌ์šฉํ•˜์„ธ์š”.
๊ฐ€์ƒ ๋ฐ๋ชจ
๊ฐ€์ƒ ํˆฌ์–ด๋ฅผ ํ†ตํ•ด ์ด ์ œํ’ˆ์— ๋Œ€ํ•ด ์ž์„ธํžˆ ์•Œ์•„๋ณด๊ณ  ์ž‘๋™ํ•˜๋Š” ๋ชจ์Šต์„ ํ™•์ธํ•ด ๋ณด์„ธ์š”

ํŠน์ง•

  • ์™„์ „ ํ†ตํ•ฉ ์‹œ์Šคํ…œ
  • ํ™•์žฅ ๊ฐ€๋Šฅ ํ˜•์‹(1-, 4- ๋ฐ 8-plate ๊ธฐ๊ธฐ)
  • ๊ณ ๊ธ‰ ๋ฉ€ํ‹ฐํ”Œ๋ ‰์‹ฑ ๊ธฐ๋Šฅ(์ตœ๋Œ€ 12ํ”Œ๋ ‰์Šค)
  • LSS ์—ผ๋ฃŒ๋ฅผ ์œ„ํ•œ ์ตœ๋Œ€ 6๊ฐœ์˜ ํ‘œ์ค€ ์ฑ„๋„๊ณผ 2๊ฐœ์˜ ํ˜ผ์„ฑ ์ฑ„๋„
  • ์œ ์—ฐ์„ฑ ์žˆ๋Š” ์ƒ˜ํ”Œ ์ฒ˜๋ฆฌ๋Ÿ‰
  • ์•ฝ 2์‹œ๊ฐ„ ๋‚ด์— ํฌ๊ด„์ ์ธ ๊ฒฐ๊ณผ ์‚ฐ์ถœ

์ œํ’ˆ ์„ธ๋ถ€ ์ •๋ณด

QIAcuity Digital PCR System์€ ๋Œ์—ฐ๋ณ€์ด ๊ฒ€์ถœ, ๋ณต์ œ ์ˆ˜ ๋ณ€์ด(Copy Number Variation, CNV), ์œ ์ „์ž ๋ฐœํ˜„ ์—ฐ๊ตฌ, ์œ ์ „์ž ํŽธ์ง‘ ๋ถ„์„ ๋“ฑ์— ๋Œ€ํ•œ ์ •๋ฐ€ํ•˜๊ณ  ๋ฉ€ํ‹ฐํ”Œ๋ ‰์‹ฑ๋œ ์ •๋Ÿ‰ํ™” ๊ฒฐ๊ณผ๋ฅผ ์ œ๊ณตํ•˜๋„๋ก ์„ค๊ณ„๋˜์—ˆ์Šต๋‹ˆ๋‹ค. ์ด ๋‚˜๋…ธํ”Œ๋ ˆ์ดํŠธ ๊ธฐ๋ฐ˜ ์‹œ์Šคํ…œ์€ ๋ถ„ํš, ์—ด์ˆœํ™˜(thermocycling) ๋ฐ ์ด๋ฏธ์ง•์˜ ํ‘œ์ค€ dPCR ์›Œํฌํ”Œ๋กœ์šฐ๋ฅผ ์ตœ์†Œํ•œ์˜ ์ง์ ‘ ์ž‘์—… ์‹œ๊ฐ„์œผ๋กœ ์ž๋™ํ™”๋œ ํ”Œ๋žซํผ์— ์™„๋ฒฝํ•˜๊ฒŒ ํ†ตํ•ฉํ•ฉ๋‹ˆ๋‹ค.

์ด ์‹œ์Šคํ…œ์€ QIAcuity Nanoplates, ์‹œ์•ฝ, ๋ถ„์„๊ณผ ํ•จ๊ป˜ ์‚ฌ์šฉ๋ฉ๋‹ˆ๋‹ค.

๊ฐ€์ƒ ๋ฐ๋ชจ๋ฅผ ํ†ตํ•ด QIAcuity์— ๋Œ€ํ•ด ์ž์„ธํžˆ ์•Œ์•„๋ณด์„ธ์š”.

์„ฑ๋Šฅ

QIAcuity Digital PCR System์€ ๋ชจ๋“  ์‹คํ—˜์‹ค์—์„œ ์ ˆ๋Œ€ ์ •๋Ÿ‰ํ™”๋ฅผ ํ•ฉ๋ฆฌ์ ์ธ ๋น„์šฉ์œผ๋กœ ํ•  ์ˆ˜ ์žˆ๊ฒŒ ํ•ฉ๋‹ˆ๋‹ค. ์›Œํฌ์–ด์›จ์ด ์ž๋™ํ™”๋Š” ์ตœ์†Œํ•œ์˜ ์ž‘์—… ์‹œ๊ฐ„์œผ๋กœ ๋ถ„ํš, ์—ด์ˆœํ™˜(thermocycling) ๋ฐ ์ด๋ฏธ์ง•์˜ ์ „์ฒด ๋””์ง€ํ„ธ PCR ์›Œํฌํ”Œ๋กœ์šฐ๋ฅผ ํ•˜๋‚˜์˜ ๊ธฐ๊ธฐ๋กœ ํ†ตํ•ฉํ•˜์—ฌ ๊ฐ„์†Œํ™”ํ•ฉ๋‹ˆ๋‹ค. ๋˜ํ•œ ํ˜„์žฌ qPCR ๋ถ„์„ ํ•ญ๋ชฉ์„ QIAcuity Digital PCR System์— ์‰ฝ๊ฒŒ ์ ์šฉํ•  ์ˆ˜ ์žˆ์Šต๋‹ˆ๋‹ค. qPCR์—์„œ ์ „ํ™˜ํ•  ๋•Œ ํ”Œ๋ ˆ์ดํŠธ ์‚ฌ์šฉ ๋ฐฉ์‹์—๋Š” ๋ณ€ํ™”๊ฐ€ ํ•„์š” ์—†์œผ๋ฏ€๋กœ ์•ฝ 2์‹œ๊ฐ„ ๋‚ด์— ๋น ๋ฅธ ๋ถ„์„ ํ•ญ๋ชฉ ์„ค์ •๊ณผ ๋น ๋ฅธ ๊ฒฐ๊ณผ๋ฅผ ์–ป์„ ์ˆ˜ ์žˆ์Šต๋‹ˆ๋‹ค.

QIAcuity ๊ธฐ๊ธฐ - ๊ธฐ๋Šฅ ๋ฐ ์‚ฌ์–‘

ํŠน์ง• QIAcuity One 2plex QIAcuity One 5plex  QIAcuity Four QIAcuity Eight
์ฒ˜๋ฆฌ ํ”Œ๋ ˆ์ดํŠธ 1 1 4 8
๊ฒ€์ถœ ์ฑ„๋„ 2 81)
(6+2 hybrid2)
81)
(6+2 hybrid2)
81)
(6+2 hybrid2)
๋ฉ€ํ‹ฐํ”Œ๋ ‰์‹ฑ ๊ธฐ๋Šฅ  4 123)1)  123)1)  123)1) 
์„œ๋ชจ์‚ฌ์ดํด๋Ÿฌ 1 1 1 2
๊ฒฐ๊ณผ๊นŒ์ง€ ๊ฑธ๋ฆฌ๋Š” ์‹œ๊ฐ„ ์•ฝ 2์‹œ๊ฐ„

์•ฝ 2์‹œ๊ฐ„

์ฒซ ๋ฒˆ์งธ ํ”Œ๋ ˆ์ดํŠธ๋Š” ์•ฝ 2์‹œ๊ฐ„

์ดํ›„ ํ”Œ๋ ˆ์ดํŠธ๋‹น ์•ฝ 80๋ถ„

์ฒซ ๋ฒˆ์งธ ํ”Œ๋ ˆ์ดํŠธ๋Š” ์•ฝ 2์‹œ๊ฐ„

์ดํ›„ ํ”Œ๋ ˆ์ดํŠธ๋‹น ์•ฝ 40๋ถ„

์ฒ˜๋ฆฌ๋Ÿ‰(๊ทผ๋ฌด์ผ ํ•˜๋ฃจ์— ์ฒ˜๋ฆฌํ•˜๋Š” ์ƒ˜ํ”Œ๋Ÿ‰)

์ตœ๋Œ€ 384๊ฐœ(96-well)

์ตœ๋Œ€ 96๊ฐœ(24-well)

์ตœ๋Œ€ 384๊ฐœ(96-well)

์ตœ๋Œ€ 96๊ฐœ(24-well)

์ตœ๋Œ€ 672๊ฐœ(96-well)

์ตœ๋Œ€ 168๊ฐœ(24-well)

์ตœ๋Œ€ 1,248๊ฐœ(96-well)

์ตœ๋Œ€ 312๊ฐœ(24-well)

1) ๋‹ค์ค‘ํ™” >5plex์˜ ๊ฒฝ์šฐ QIAcuity High Multiplex Probe PCR Kit ์‚ฌ์šฉ์ด ํ•„์š”ํ•ฉ๋‹ˆ๋‹ค.
2) ํ•˜์ด๋ธŒ๋ฆฌ๋“œ ์ฑ„๋„์€ Long Stokes Shift(LSS) ์—ผ๋ฃŒ์— ์‚ฌ์šฉ๋ฉ๋‹ˆ๋‹ค
3) 6๊ฐœ์˜ ํ‘œ์ค€ ์ฑ„๋„์—์„œ ์ง„ํญ ๋ฉ€ํ‹ฐํ”Œ๋ ‰์‹ฑ์„ ์‚ฌ์šฉํ•˜์—ฌ 12๊ฐœ์˜ ํ‘œ์ ์„ ๋ณ‘๋ ฌ๋กœ ๊ฒ€์ถœํ•  ์ˆ˜ ์žˆ์Šต๋‹ˆ๋‹ค. ์‹ฑ๊ธ€ ํ”Œ๋ ‰์Šค LSS ์—ผ๋ฃŒ์™€ ์ง„ํญ ๋ฉ€ํ‹ฐํ”Œ๋ ‰์‹ฑ์„ ์œ„ํ•œ ํ˜ผ์„ฑ ์ฑ„๋„์„ ๊ฒฐํ•ฉํ•˜๋ฉด ๊ฐ€๋Šฅํ•œ ์ด๋ฉ€ํ‹ฐํ”Œ๋ ‰์Šค ํšŸ์ˆ˜๊ฐ€ 14ํšŒ๋กœ ๋Š˜์–ด๋‚  ์ˆ˜ ์žˆ์Šต๋‹ˆ๋‹ค. ๊ทธ๋Ÿฌ๋‚˜ ๋ฐ˜์‘ ํ˜ผํ•ฉ๋ฌผ์— ์‚ฌ์šฉ๋˜๋Š” ๋ชจ๋“  ๋ถ„์„ ํ•ญ๋ชฉ์— ๋Œ€ํ•œ ์ตœ์ ํ™” ์š”๊ตฌ์™€ ํ•ด๋‹น ๋ˆ„ํ™” ๋ณด์ƒ์œผ๋กœ ์ธํ•ด ์ด๋Ÿฌํ•œ ๊ฒฐํ•ฉ์€ ๊ถŒ์žฅ๋˜์ง€ ์•Š์Šต๋‹ˆ๋‹ค.

 

์›๋ฆฌ

ํ”ผํŽซํŒ… ๋ฐ ๋กœ๋”ฉ, ์‹คํ—˜ ์‹คํ–‰, ๊ฒฐ๊ณผ ๋ถ„์„์˜ ๊ฐ„๋‹จํ•œ 3๋‹จ๊ณ„๋กœ ์•ฝ 2์‹œ๊ฐ„ ๋‚ด์— ์›ํ•˜๋Š” dPCR ๊ฒฐ๊ณผ๋ฅผ ์–ป์„ ์ˆ˜ ์žˆ์Šต๋‹ˆ๋‹ค.

๋‚˜๋…ธํ”Œ๋ ˆ์ดํŠธ์—์„œ์˜ dPCR ๋ฐ˜์‘ ์›๋ฆฌ๋Š” ์—ฌ๊ธฐ์— ์„ค๋ช…๋˜์–ด ์žˆ์Šต๋‹ˆ๋‹ค.

์ ˆ์ฐจ

qPCR ์‹คํ—˜๊ณผ ๋งˆ์ฐฌ๊ฐ€์ง€๋กœ ์ƒ˜ํ”Œ ์ค€๋น„์—๋Š” ๋งˆ์Šคํ„ฐ ๋ฏน์Šค, ํ”„๋กœ๋ธŒ ๋ฐ ํ”„๋ผ์ด๋จธ๋ฅผ 96-well ๋˜๋Š” 24-well ๋‚˜๋…ธํ”Œ๋ ˆ์ดํŠธ๋กœ ์˜ฎ๊ธด ๋‹ค์Œ ์ƒ˜ํ”Œ์„ ์ถ”๊ฐ€ํ•˜๋Š” ์ž‘์—…์ด ํฌํ•จ๋ฉ๋‹ˆ๋‹ค. ์ด ์‹œ์Šคํ…œ์€ ๋ถ„ํš, ์—ด์ˆœํ™˜, ์ด๋ฏธ์ง• ๊ธฐ๋Šฅ์„ ์™„์ „ ์ž๋™ํ™”๋œ ํ•˜๋‚˜์˜ ๊ธฐ๊ธฐ์— ํ†ตํ•ฉํ•˜์—ฌ ์‚ฌ์šฉ์ž๊ฐ€ 2์‹œ๊ฐ„ ์ด๋‚ด์— ์ƒ˜ํ”Œ์—์„œ ๊ฒฐ๊ณผ๋ฅผ ์–ป์„ ์ˆ˜ ์žˆ๋„๋ก ํ•ฉ๋‹ˆ๋‹ค. ์‚ฌ์šฉ์ž๋Š” ์†Œํ”„ํŠธ์›จ์–ด ์ œํ’ˆ๊ตฐ์—์„œ ๋ถ„์„์„ ์ˆ˜ํ–‰ํ•  ์ˆ˜ ์žˆ์œผ๋ฉฐ, ํ‘œ์  ์—ผ๊ธฐ์„œ์—ด์˜ ๋งˆ์ดํฌ๋กœ๋ฆฌํ„ฐ๋‹น ๋ณต์ œ ๋†๋„๋ฟ๋งŒ ์•„๋‹ˆ๋ผ ์–‘์„ฑ ์ƒ˜ํ”Œ์ด๋‚˜ NTC์™€ ๊ฐ™์€ ์ •๋„ ๊ด€๋ฆฌ๋„ ์ œ๊ณต๋ฉ๋‹ˆ๋‹ค. ์ด ๋ถ„์„์€ ๋˜ํ•œ ๋™์ผํ•œ ๊ทผ๊ฑฐ๋ฆฌ ํ†ต์‹ ๋ง(Local Area Network, LAN) ๋‚ด์˜ ์›๊ฒฉ ์ปดํ“จํ„ฐ๋กœ ํ™•์žฅ๋  ์ˆ˜ ์žˆ์Šต๋‹ˆ๋‹ค.

์‘์šฉ ๋ถ„์•ผ

QIAcuity ๊ธฐ๊ธฐ๋Š” QIAcuity Nanoplates ๋ฐ QIAcuity PCR ํ‚คํŠธ์™€ ํ•จ๊ป˜ ๋‹ค์Œ์„ ํฌํ•จํ•œ ๋””์ง€ํ„ธ PCR ์• ํ”Œ๋ฆฌ์ผ€์ด์…˜์„ ์ง€์›ํ•ฉ๋‹ˆ๋‹ค.

  • ํฌ๊ท€ ๋Œ์—ฐ๋ณ€์ด ๊ฒ€์ถœ
  • ๋ณต์ œ ์ˆ˜ ๋ณ€์ด ๋ถ„์„
  • ์œ ์ „์ž ๋ฐœํ˜„ ๋ถ„์„
  • ๋ณ‘์›์ฒด ๊ฒ€์ถœ
  • ์œ ์ „ํ˜• ๋ถ„์„
  • miRNA ์—ฐ๊ตฌ
  • ์„ธํฌ ๋ฐ ์œ ์ „์ž ์น˜๋ฃŒ

 

์†Œํ”„ํŠธ์›จ์–ด

๊ธฐ๊ธฐ์™€ ํ•จ๊ป˜ ์ œ๊ณต๋˜๊ณ  ๋ณ„๋„์˜ ์ปดํ“จํ„ฐ์— ์„ค์น˜๋œ QIAcuity Software Suite๋Š” ํ•œ ๋Œ€์˜ ๊ธฐ๊ธฐ์— ์ง์ ‘ ์—ฐ๊ฒฐํ•˜๊ฑฐ๋‚˜ ๊ธฐ์กด ๊ทผ๊ฑฐ๋ฆฌ ํ†ต์‹ ๋ง(Local Area Network, LAN)์„ ์‚ฌ์šฉํ•˜์—ฌ ํ•œ ๋Œ€ ์ด์ƒ์˜ QIAcuity ๊ธฐ๊ธฐ๋ฅผ ์ œ์–ดํ•ฉ๋‹ˆ๋‹ค. QIAcuity Software Suite๋ฅผ ์‚ฌ์šฉํ•˜์—ฌ ๋””์ง€ํ„ธ PCR ์‹คํ—˜, ์ƒ˜ํ”Œ ๋ฐ ๋ฐ˜์‘ ํ˜ผํ•ฉ๋ฌผ์„ ์ •์˜ํ•˜๊ณ  ๋‚˜๋…ธํ”Œ๋ ˆ์ดํŠธ์— ๋ฐฐ์ •ํ•˜๊ณ  QIAcuity ๊ธฐ๊ธฐ๋กœ ์ „์†กํ•  ์ˆ˜ ์žˆ์Šต๋‹ˆ๋‹ค. ์‹คํ–‰ ํ›„ ๋ฐ์ดํ„ฐ๋ฅผ ๋ถ„์„ํ•˜๊ณ  ๋ณด๊ณ ์„œ๋ฅผ ๋งŒ๋“ค๊ณ  ์™ธ๋ถ€ ๋ถ„์„์„ ์œ„ํ•ด ๋ฐ์ดํ„ฐ๋ฅผ ๋‚ด๋ณด๋‚ผ ์ˆ˜ ์žˆ์Šต๋‹ˆ๋‹ค. ์ด ์†Œํ”„ํŠธ์›จ์–ด๋Š” ๋ฐ˜๋ณต๋˜๋Š” ํ”Œ๋ ˆ์ดํŠธ ๋ ˆ์ด์•„์›ƒ ๋˜๋Š” ํ”Œ๋ ˆ์ดํŠธ ์‹คํ–‰ ๋งค๊ฐœ๋ณ€์ˆ˜์— ์‰ฝ๊ฒŒ ์•ก์„ธ์Šคํ•  ์ˆ˜ ์žˆ๋„๋ก ํ•˜๋Š” ์—ฌ๋Ÿฌ ํ…œํ”Œ๋ฆฟ ๊ธฐ๋Šฅ์„ ์ œ๊ณตํ•˜์—ฌ ๋””์ง€ํ„ธ PCR ๊ฒฝํ—˜์„ ๋”์šฑ ํ–ฅ์ƒํ•ฉ๋‹ˆ๋‹ค.

LAN์— ํ†ตํ•ฉ๋˜๋ฉด ์ปดํ“จํ„ฐ๊ฐ€ LAN์„ ํ†ตํ•ด ํด๋ผ์ด์–ธํŠธ ์—ญํ• ์„ ํ•˜๋Š” ๋‹ค๋ฅธ ์ปดํ“จํ„ฐ์— ์•ก์„ธ์Šคํ•  ์ˆ˜ ์žˆ๋Š” ์„œ๋ฒ„๋กœ์„œ QIAcuity Software Suite ๊ธฐ๋Šฅ์„ ํ˜ธ์ŠคํŒ…ํ•ฉ๋‹ˆ๋‹ค. ์ด๋ฅผ ํ†ตํ•ด ์—ฌ๋Ÿฌ ์‚ฌ์šฉ์ž๊ฐ€ ์—ฌ๋Ÿฌ ์ปดํ“จํ„ฐ์— ์†Œํ”„ํŠธ์›จ์–ด๋ฅผ ์„ค์น˜ํ•˜๊ฑฐ๋‚˜ ์ธํ„ฐ๋„ท ์—ฐ๊ฒฐ์„ ํ†ตํ•ด ๋ฐ์ดํ„ฐ์— ์•ก์„ธ์Šคํ•˜๊ณ  ๊ตํ™˜ํ•  ํ•„์š” ์—†์ด ๋‹ค๋ฅธ ๋ฐฉ์ด๋‚˜ ์‚ฌ๋ฌด์‹ค์—์„œ ์†Œํ”„ํŠธ์›จ์–ด์— ์•ก์„ธ์Šคํ•˜๊ณ  ํ‘œ์ค€ ๋ธŒ๋ผ์šฐ์ €๋ฅผ ํ†ตํ•ด ๋ฐ์ดํ„ฐ๋ฅผ ๋ถ„์„ํ•  ์ˆ˜ ์žˆ์Šต๋‹ˆ๋‹ค.

์„œ๋น„์Šค

QIAGEN์˜ ๋‹ค์–‘ํ•œ ์„œ๋น„์Šค ์†”๋ฃจ์…˜์œผ๋กœ ๊ธฐ๊ธฐ๋ฅผ ๊ด€๋ฆฌํ•˜์„ธ์š”. ์š”๊ตฌ ์‚ฌํ•ญ์— ๋งž๋Š” ํŠน์ • ์„œ๋น„์Šค ๊ณ„์•ฝ์— ๋Œ€ํ•ด ์•Œ์•„๋ณด์„ธ์š”.

์ง€์›๋˜๋Š” ๋ฐ์ดํ„ฐ ๋ฐ ์ˆ˜์น˜

Kits & Consumables

dPCR Kits
dPCR Assays
dPCR Accessories
QIAcuity RCL Quant Kit image
Cat. No.: 250322

์„œ๋น„์Šค ๊ณ„ํš

QIAcuity One 2plex Full Agreement

์นดํƒˆ๋กœ๊ทธ ๋ฒˆํ˜ธ / ID.   9245362

1๋…„๊ฐ„ ์ถœ์žฅ, ๊ณต์ž„ ๋ฐ ๋ถ€ํ’ˆ์„ ํฌํ•จํ•œ ํ˜„์žฅ QIAcuity One 2plex ๊ธฐ๊ธฐ ์ˆ˜๋ฆฌ. ์˜์—…์ผ ๊ธฐ์ค€ 2์ผ ๋Œ€์‘ ์‹œ๊ฐ„. ์ „์ฒด ๊ณ„์•ฝ ๊ธฐ๊ฐ„ ๋™์•ˆ 1ํšŒ ์˜ˆ๋ฐฉ ์œ ์ง€๋ณด์ˆ˜ ํฌํ•จ.

QIAcuity One 2plex Core Agreement

์นดํƒˆ๋กœ๊ทธ ๋ฒˆํ˜ธ / ID.   9245358

1๋…„๊ฐ„ ์ถœ์žฅ, ๊ณต์ž„ ๋ฐ ์˜ˆ๋น„ ๋ถ€ํ’ˆ์„ ํฌํ•จํ•œ 1ํšŒ ํ˜„์žฅ ์ˆ˜๋ฆฌ ์„œ๋น„์Šค ๋ฐ 1ํšŒ ํ˜„์žฅ ์˜ˆ๋ฐฉ ์œ ์ง€๋ณด์ˆ˜. ์˜์—…์ผ ๊ธฐ์ค€ 5์ผ ๋Œ€์‘ ์‹œ๊ฐ„. ๊ณ„์•ฝ ๊ธฐ๊ฐ„ ๋™์•ˆ ์ถ”๊ฐ€ ์ˆ˜๋ฆฌ ์„œ๋น„์Šค์— ๋Œ€ํ•œ 10% ํ• ์ธ ํฌํ•จ.

QIAcuity One 5plex Core Agreement

์นดํƒˆ๋กœ๊ทธ ๋ฒˆํ˜ธ / ID.   9245359

1๋…„๊ฐ„ ์ถœ์žฅ, ๊ณต์ž„ ๋ฐ ์˜ˆ๋น„ ๋ถ€ํ’ˆ์„ ํฌํ•จํ•œ 1ํšŒ ํ˜„์žฅ ์ˆ˜๋ฆฌ ์„œ๋น„์Šค ๋ฐ 1ํšŒ ํ˜„์žฅ ์˜ˆ๋ฐฉ ์œ ์ง€๋ณด์ˆ˜. ์˜์—…์ผ ๊ธฐ์ค€ 5์ผ ๋Œ€์‘ ์‹œ๊ฐ„. ๊ณ„์•ฝ ๊ธฐ๊ฐ„ ๋™์•ˆ ์ถ”๊ฐ€ ์ˆ˜๋ฆฌ ์„œ๋น„์Šค์— ๋Œ€ํ•œ 10% ํ• ์ธ ํฌํ•จ.

QIAcuity Four Core Agreement

์นดํƒˆ๋กœ๊ทธ ๋ฒˆํ˜ธ / ID.   9245360

1๋…„๊ฐ„ ์ถœ์žฅ, ๊ณต์ž„ ๋ฐ ์˜ˆ๋น„ ๋ถ€ํ’ˆ์„ ํฌํ•จํ•œ 1ํšŒ ํ˜„์žฅ ์ˆ˜๋ฆฌ ์„œ๋น„์Šค ๋ฐ 1ํšŒ ํ˜„์žฅ ์˜ˆ๋ฐฉ ์œ ์ง€๋ณด์ˆ˜. ์˜์—…์ผ ๊ธฐ์ค€ 5์ผ ๋Œ€์‘ ์‹œ๊ฐ„. ๊ณ„์•ฝ ๊ธฐ๊ฐ„ ๋™์•ˆ ์ถ”๊ฐ€ ์ˆ˜๋ฆฌ ์„œ๋น„์Šค์— ๋Œ€ํ•œ 10% ํ• ์ธ ํฌํ•จ.

QIAcuity Eight Core Agreement

์นดํƒˆ๋กœ๊ทธ ๋ฒˆํ˜ธ / ID.   9245361

1๋…„๊ฐ„ ์ถœ์žฅ, ๊ณต์ž„ ๋ฐ ์˜ˆ๋น„ ๋ถ€ํ’ˆ์„ ํฌํ•จํ•œ 1ํšŒ ํ˜„์žฅ ์ˆ˜๋ฆฌ ์„œ๋น„์Šค ๋ฐ 1ํšŒ ํ˜„์žฅ ์˜ˆ๋ฐฉ ์œ ์ง€๋ณด์ˆ˜. ์˜์—…์ผ ๊ธฐ์ค€ 5์ผ ๋Œ€์‘ ์‹œ๊ฐ„. ๊ณ„์•ฝ ๊ธฐ๊ฐ„ ๋™์•ˆ ์ถ”๊ฐ€ ์ˆ˜๋ฆฌ ์„œ๋น„์Šค์— ๋Œ€ํ•œ 10% ํ• ์ธ ํฌํ•จ.

QIAcuity Four Basic Agreement

์นดํƒˆ๋กœ๊ทธ ๋ฒˆํ˜ธ / ID.   9245403

1๋…„๊ฐ„ ์ถœ์žฅ, ๊ณต์ž„ ๋ฐ ๋ถ€ํ’ˆ์„ ํฌํ•จํ•œ ํ˜„์žฅ QIAcuity Four ๊ธฐ๊ธฐ ์ˆ˜๋ฆฌ. ์˜์—…์ผ ๊ธฐ์ค€ 5์ผ ๋Œ€์‘ ์‹œ๊ฐ„. ๊ธฐ๋ณธ ๊ณ„์•ฝ ๊ธฐ๊ฐ„ ๋™์•ˆ 1ํšŒ ์˜ˆ๋ฐฉ ์œ ์ง€๋ณด์ˆ˜ ํฌํ•จ.

QIAcuity Eight Basic Agreement

์นดํƒˆ๋กœ๊ทธ ๋ฒˆํ˜ธ / ID.   9245404

1๋…„๊ฐ„ ์ถœ์žฅ, ๊ณต์ž„ ๋ฐ ๋ถ€ํ’ˆ์„ ํฌํ•จํ•œ ํ˜„์žฅ QIAcuity Eight ๊ธฐ๊ธฐ ์ˆ˜๋ฆฌ. ์˜์—…์ผ ๊ธฐ์ค€ 5์ผ ๋Œ€์‘ ์‹œ๊ฐ„. ๊ธฐ๋ณธ ๊ณ„์•ฝ ๊ธฐ๊ฐ„ ๋™์•ˆ 1ํšŒ ์˜ˆ๋ฐฉ ์œ ์ง€๋ณด์ˆ˜ ํฌํ•จ.

QIAcuity One 5plex Full Agreement

์นดํƒˆ๋กœ๊ทธ ๋ฒˆํ˜ธ / ID.   9245363

1๋…„๊ฐ„ ์ถœ์žฅ, ๊ณต์ž„ ๋ฐ ๋ถ€ํ’ˆ์„ ํฌํ•จํ•œ ํ˜„์žฅ QIAcuity One 5plex ๊ธฐ๊ธฐ ์ˆ˜๋ฆฌ. ์˜์—…์ผ ๊ธฐ์ค€ 2์ผ ๋Œ€์‘ ์‹œ๊ฐ„. ์ „์ฒด ๊ณ„์•ฝ ๊ธฐ๊ฐ„ ๋™์•ˆ 1ํšŒ ์˜ˆ๋ฐฉ ์œ ์ง€๋ณด์ˆ˜ ํฌํ•จ.

QIAcuity Four Full Agreement

์นดํƒˆ๋กœ๊ทธ ๋ฒˆํ˜ธ / ID.   9245364

1๋…„๊ฐ„ ์ถœ์žฅ, ๊ณต์ž„ ๋ฐ ๋ถ€ํ’ˆ์„ ํฌํ•จํ•œ ํ˜„์žฅ QIAcuity Four ๊ธฐ๊ธฐ ์ˆ˜๋ฆฌ. ์˜์—…์ผ ๊ธฐ์ค€ 2์ผ ๋Œ€์‘ ์‹œ๊ฐ„. ์ „์ฒด ๊ณ„์•ฝ ๊ธฐ๊ฐ„ ๋™์•ˆ 1ํšŒ ์˜ˆ๋ฐฉ ์œ ์ง€๋ณด์ˆ˜ ํฌํ•จ.

QIAcuity Eight Full Agreement

์นดํƒˆ๋กœ๊ทธ ๋ฒˆํ˜ธ / ID.   9245365

1๋…„๊ฐ„ ์ถœ์žฅ, ๊ณต์ž„ ๋ฐ ๋ถ€ํ’ˆ์„ ํฌํ•จํ•œ ํ˜„์žฅ QIAcuity Eight ๊ธฐ๊ธฐ ์ˆ˜๋ฆฌ. ์˜์—…์ผ ๊ธฐ์ค€ 2์ผ ๋Œ€์‘ ์‹œ๊ฐ„. ์ „์ฒด ๊ณ„์•ฝ ๊ธฐ๊ฐ„ ๋™์•ˆ 1ํšŒ ์˜ˆ๋ฐฉ ์œ ์ง€๋ณด์ˆ˜ ํฌํ•จ.

FAQ

Is it possible to change voltage set-up from 110V to 230V on the QIAcuity instruments?

This is not needed. The QIAcuity is equipped with a flexible power supply technology and operates within a range of 100โ€“240V AC, 50/60 Hz, 1500 VA (max). 

FAQ-3761
Can I see error codes on the instrument touchscreen?

The instrument software GUI shows error codes including a description and information how to resolve the error. The instrument touchscreen shows an alarm icon in the upper right corner that turns red in case of an instrument failure. Accessing the System Status in the Tool tab allows users to clear errors. Rebooting of the instrument is required to complete the removal of the error.  Please do not skip this step. You may always contact QIAGEN Technical Services in case of any question. 

FAQ-3763
What is the scope of a regular maintenance of the QIAcuity?

The user manual contains instructions on how to perform a regular cleaning and decontamination, and how to replace air filters on the QIAcuity instruments. A regular maintenance reduces the dust in the instrument and therefore minimizes the presence of dust particles on the nanoplate, which might interfere with the plate analysis.

FAQ-3765
What is the impact of not applying the latest VPF? Can I reanalyze previously obtained results after installing the latest VPF?

If you had run a nanoplate for which the installed VPF misses the specific factor, the software will notify you. If you then analyze without the specific VPF, the impact depends on the variation of the partition volume of the new Nanoplate batch compared to the latest. Typically this variation is ยฑ6โ€“7% (approx. 5% CV over the entire plate). The analysis may be repeated after updating the VPF file. After installing the latest VPF and re-analysis of the run, a copy of the plate is generated in the QIAcuity Software Suite including the new results. 

FAQ-3769
Can I see on the QIAcuity Software Suite report file if the VPF (Volume Precision Factor) has been used or not?

Yes, the report includes a notification if the matching VPF was missing and, therefore, not applied to the analysis. If the matching VPF was applied there is no notification on the report. 

FAQ-3770
Is it necessary to reanalyze a plate with VPF (Volume Precision Factor) that was already processed using a QIAcuity instrument that was purchased in 2020?

If you had analyzed your nanoplates without VFP, the impact depends on the variation of the partition volume of the new nanoplate batch compared to the latest. The VPF reduces the CV from approximately 5% to 2%. We recommend to reanalyze results in case the data originated from different wells (e.g., copy number variations or gene expression data sets for which the reference sample was measured in a different well). Results obtained across different plates should also be r-analyzed. A reanalysis is not required for assay data that were analyzed within the same well (e.g., mutation rate determination using two channels within the same well).

FAQ-3771
Can I prepare a dPCR reaction directly in QIAcuity Nanoplate?

A standard PCR plate is required to set up dPCR reaction before transferring it to the nanoplate to ensure a proper mixing of the reaction mix before partitioning. 

FAQ-3774
Can I use a custom master mix instead of a QIAGEN master mix?

QIAGEN master mixes are optimized for nanoplate microfluidics and are recommended to be used with our dPCR system. They also include an optimized reference dye required for proper analysis.

FAQ-3777
How to prepare DNA prior to dPCR?

All DNA samples used in reaction mixes should show similar quality and quantity, which can easily be assessed using UV spectrophotometry. DNA samples with an average length of โ‰ฅ20 kb (e.g., genomic DNA purified via spin column with silica membrane) should be fragmented by restriction digestion before partitioning. Enzymatic fragmentation of larger DNA ensures an even distribution of template throughout the QIAcuity Nanoplate, which in turn leads to an accurate and precise quantification.

FAQ-3778
What are the storage conditions and expiry date of QIAcuity consumables?

The QIAcuity Probe PCR Kit should be stored immediately upon receipt at โ€“30 to โ€“15ยฐC in a constant-temperature freezer and protected from light. The QIAcuity Probe PCR master mix can also be stored protected from light at 2โ€“8ยฐC. Components are stable for 12 months, unless otherwise indicated on the label. 
The QIAcuity EG PCR Kit should be stored immediately upon receipt at โ€“30 to โ€“15ยฐC in a constant-temperature freezer and protected from light. The QIAcuity EG PCR master mix can also be stored protected from light at 2โ€“8ยฐC. Components are stable for 6 months, unless otherwise indicated on the label. 
The QIAcuity Nanoplates does not have expiry date and are stable for at least 1 year when stored at RT. 

FAQ-3780
Can I use the QIAcuity Nanoplate in more than one runs?

The plate is designed for a single use run. For example, even if only 30 samples are loaded into the 96-well plate, a whole plate will be sealed by the roller. It can't be unsealed and used for another run. The QIAcuity Software wonโ€™t allow to set up a separate experiment for the same nanoplate to avoid that previously processed plates being not partitioned a second time.

FAQ-3781
Can I optimize a dPCR assay on the QIAcuity using gradient temperature?

An essential temperature gradient functionality was introduced with software version 2.5. When updating older software versions to 2.5, each QIAcuity instrument will offer the temperature gradient and may be used to find the best cycling temperature for new dPCR assays. When running a QIAcuity Four or a QIAcuity Eight, all plates may have their own temperature profile, including the option for a temperature gradient.

FAQ-3783
What is the VPF (Volume Precision Factor)?

The VPF provides a set of well-specific and molding form-specific factors used to specify the exact reaction volume of a nanoplate, thus increasing the concentration calculation of each well. 

FAQ-3784
When and how often do I need a new VPF (Volume Precision Factor)?

 In general, nanoplates provide partitions of fixed sizes that enable a very precise way of sample concentration calculation. If a new molding form is used for nanoplate manufacturing, potential variation of partition sizes can be addressed by applying the molding form-specific VPF. Thus, each time a new molding form is used, a new VPF is created and made available. Currently, the VPF is updated once every 3โ€“6 months.

FAQ-3785
Is a standard curve needed in dPCR?

In dPCR we measure the absolute concentration of targets at endpoint reaction. Concentrations of unknowns can be determined based on dPCR results observed (number of negatives, number of positives, and partition volume analyzed).

FAQ-3786